Removing and installing temperature sender before particulate filter G506 on Audi: 20 steps, engines ASB, AVB, AVF, AWX.
Workshop procedure for AUDI — the exact step sequence and torque figures, straight from real workshop data.
🧭 Before you start
Fits: Audi A6 C6 (4F, 2004–2011)
- Renewed: gaskets
Don't miss
- The temperature sender before particulate filter G506 is removed LATER.Disregard (item 1).
- When installing, make sure that temperature sender before particulate filter G506 is positioned parallel to flange area of particulate filter.
🔧 Engine codes this applies to
📋 Procedure
- Pull dipstick (1) out of guide tube.
- Pull off engine cover panel (arrows).
- Re-insert dipstick in guide tube.
- Remove bolts (arrows).
- Remove air ducts (1) and (2).
- Release two retaining clips (arrows) and detach top section of air cleaner housing.
- Unplug electrical connector (1) at air mass meter G70.
- Loosen hose clip (4) to remove air intake hose.
- If fitted, disconnect vacuum hose (2) and lift vacuum unit (3) together with air flap off air cleaner housing.
- Disengage bottom section of air cleaner housing from retaining pin and remove.
- Slacken temperature sender before particulate filter G506(item 2). [Note: The temperature sender before particulate filter G506 is removed LATER.Disregard (item 1).]
- Remove front exhaust pipe .
- Open quick-release fasteners (2) and remove rear noise insulation.
- Take electrical connector (2) for temperature sender before particulate filter G506 out of bracket.
- Unplug electrical connector and move wiring clear.
- Unscrew securing nuts connecting turbocharger to particulate filter (1 ... 3) and push particulate filter slightly towards the rear.
- Detach temperature sender before particulate filter G506. [Note: Renew gaskets and self-locking nuts.Fit all heat insulation sleeves in the original position when installing.Secure all hose connections with the correct type of hose clips (same as original equipment) Parts catalogue.Fit all cable ties in the original positions when installing.]
- When installing, make sure that temperature sender before particulate filter G506 is positioned parallel to flange area of particulate filter.
- Install front exhaust pipe .
- Align exhaust system so it is free of stress .
Other AUDI procedures
- Removing and installing intake manifold (left and right bottom sections) - vehicles up to 10.2004
- Removing and installing mounting plate for engine oil cooler, pressure control valve and oil filter housing
- Checking tandem pump - vehicles with 1.9 ltr. and 2.0 ltr. 2V engine
- Removing and installing coolant pipe (top right)
- Removing and installing charge air cooler (right-side)
- Removing and installing toothed belt · 56 torque figures
- Removing engine · 41 torque figures
- Removing camshaft timing chain from camshafts · 38 torque figures
- Installing engine · 36 torque figures
- Removing and installing camshaft timing chain · 29 torque figures
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
The figures on this page come from manufacturer workshop documentation and are shown as they are. The page is assembled automatically from that data — it is not written by an AI. The AI works in the chat, where it answers for your specific car. It writes nothing here.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix →Workshop data on this page last updated 20 Sep 2026.