TorqFix

Repairing components of refrigerant circuit, vehicles ▸ 09.00: VW

Repairing components of refrigerant circuit, vehicles ▸ 09.00 — VW. Original source text. Check the document conditions against your vehicle.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

ℹ️ Torque figures below come verbatim from workshop data — always cross-check against your vehicle's factory manual before final tightening.

Repairing components of refrigerant circuit, vehicles ▸ 09.00
Note
The refrigerant must be extracted beforehand, e.g. with air conditioner service station
VAS 6007A or later model.
The previously used service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
Safety measures when working with an extracted refrigerant circuit (see the separate procedure)
. Notes on repair work to vehicles with air conditioning and on handling refrigerant.
Only the components marked with an
“*” can be renewed without opening and evacuating the refrigerant circuit.
To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
The colour coding of O-rings for R134a refrigerant circuits has been discontinued. Coloured and black O-rings are used.
Refrigerant hose
Between air conditioner compressor and reservoir.
Thread 28 mm ∅; pitch 1.5 mm
42 ± 4 Nm
O-ring
17.2 mm; 1.8 mm
Refrigerant hose
Between evaporator and condenser.
Thread 20 mm ∅; pitch 1.5 mm
15 ± 1.5 Nm
O-ring
10.8 mm; 1.8 mm
Restrictor
Removing and installing restrictor, function of restrictor (see the separate procedure).
O-ring
7.5 mm; 1.5 mm
O-ring
10.8 mm; 1.8 mm
Evacuating and charging valve
High-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing (see the separate procedure)
Capacities (see the separate procedure)
Protective cap*
O-ring
10.8 mm; 1.8 mm
O-ring
17.2 mm; 1.8 mm
Evaporator
In passenger compartment
Removal (see the separate procedure)
, Dismantling and assembling the evaporator housing.
Hexagon socket head bolt
10 ± 1 Nm
Protective cap*
Evacuating and charging valve
Low-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing (see the separate procedure)
Capacities (see the separate procedure)
O-ring
7.6 mm; 1.8 mm
Refrigerant line
Between evaporator and reservoir.
Socket head bolts
25 ± 2.5 Nm
Qty. 2
O-ring
11.1 mm; 1.8 mm
O-ring
23.8 mm; 2.4 mm
Air conditioner compressor
With air conditioning system magnetic clutch
N25.
Manufacturer, Zexel (DCW-17D)
Overview - air conditioner compressor manufacturers (see the separate procedure)
High-pressure safety valve
Checking (see the separate procedure)
Air conditioner compressor
With air conditioning system magnetic clutch
N25.
Manufacturer, Denso (7SB-16C)
Overview - air conditioner compressor manufacturers (see the separate procedure)
O-ring
23.8 mm; 2.4 mm
O-ring
11.1 mm; 1.8 mm
Socket head bolts
25 ± 2.5 Nm
Qty. 2
Air conditioning system magnetic clutch
N25
*
Repairs to the magnetic clutch with the air conditioner compressor installed should only be performed only as an exception.
Manufacturer Zexel
Repairing magnetic clutch (see the separate procedure)
Manufacturer: Denso
Repairing magnetic clutch (see the separate procedure)
Condenser
Removing (see the separate procedure)
Thread 20 mm ∅; pitch 1.5 mm
Thread 24 mm ∅; pitch 1.5 mm
O-ring
14 mm; 1.8 mm
Thread 24 mm ∅; pitch 1.5 mm
30 ± 3 Nm
O-ring
10.8 mm; 1.8 mm
Refrigerant hose
Between air conditioner compressor and condenser
Thread 20 mm ∅; pitch 1.5 mm
15 ± 1.5 Nm
O-ring
7.6 mm; 1.8 mm
Air conditioning system pressure switch
F129
Removing and installing:
Torque setting 8 Nm
Renew O-ring (note part number)
The pressure switch can be removed without extracting the refrigerant from the refrigerant circuit.
Checking: use vehicle diagnosis, testing and information system
VAS 5051A in
“guided fault finding” function
Check air conditioning system pressure switch
F129 (see the separate procedure)
Renewing: vehicles ▸ 09.00 (see the separate procedure)
Function:
Switches radiator fan
V7 to next higher speed when pressure increases in refrigerant circuit.
Switches off the air conditioner when the pressure is too high (for example, insufficient engine cooling).
Switches off the air conditioner when the pressure is too low (for example, loss of refrigerant).
Reservoir with dryer cartridge
Functions (see the separate procedure).
Under certain conditions, it is not necessary to renew the reservoir every time that the refrigerant circuit is opened. Refer to workshop manual Heating, ventilation, air conditioning system;
“Air conditioning system with refrigerant R134a”
Rep. Gr.
00
Technical data, Renewing components.
Removing and installing (see the separate procedure)
Thread 28 mm ∅; pitch 1.5 mm
42 ± 4 Nm
O-ring
17.2 mm; 1.8 mm

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.