Renewing refrigerant circuit components, vehicles ▸ 02.00: VW
Renewing refrigerant circuit components, vehicles ▸ 02.00 — VW. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
ℹ️ Torque figures below come verbatim from workshop data — always cross-check against your vehicle's factory manual before final tightening.
Renewing refrigerant circuit components, vehicles ▸ 02.00
WARNING
Danger of freezing injuries.
If the refrigerant circuit has not been evacuated, refrigerant will escape.
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again.
Note
The refrigerant circuit must be purged with refrigerant R134a:
If dirt or other contamination is in the circuit.
If during the evacuation of a leak-tight refrigerant circuit the vacuum is not maintained at the gauge (there is moisture in the refrigerant circuit and this generates vapour pressure).
If the refrigerant circuit has been left open for longer than normally required for repairs (e.g. following an accident).
When pressure and temperature measurements in the refrigerant circuit indicate that there is moisture in the refrigerant circuit.
There is doubt about the amount of refrigerant oil in the refrigerant circuit.
The air conditioner compressor has to be exchanged because of internal damage (e.g. noisy or lack of power).
The procedure for purging can be found in the workshop manual
“Air conditioning system with refrigerant R134a VW”
Rep. Gr.
00
, Technical data, Clearing refrigerant circuit of contaminants.
The refrigerant must be extracted beforehand, e.g. with air conditioner service station
VAS 6007A (or later model).
Releasing refrigerant into the environment is a punishable offence.
The previously used service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
Safety measures when working with an extracted refrigerant circuit (see the separate procedure)
. Notes on repair work to vehicles with air conditioning and on handling refrigerant.
To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
The colour coding of O-rings for R134a refrigerant circuits has been discontinued. Coloured and black O-rings are used.
Under certain conditions, it is not necessary to renew the receiver with dryer every time that the refrigerant circuit is opened. Information can be found in the workshop information under
“Air conditioning system with refrigerant R134a”
Rep. Gr.
00
“Renewing components”.
Only the components marked with an
“*” can be renewed without opening and evacuating the refrigerant circuit.
O-ring
10.8 mm; 1.82 mm
O-ring
7.6 mm; 1.82 mm
Evacuating and charging valve
High-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing (see the separate procedure)
Capacities (see the separate procedure).
Socket head combi-bolt
7 ± 1 Nm
Refrigerant hose
From air conditioner compressor to condenser.
With damper
O-ring
10.8 mm; 1.82 mm
3/4" thread - 16 UNF
Note
Counterhold threaded connection with suitable tool when loosening and tightening.
30 ± 2 Nm
Condenser
Removing (see the separate procedure)
5/8" thread - 18 UNF
Note
Counterhold threaded connection with suitable tool when loosening and tightening.
16.5 ± 1.6 Nm
O-ring
7.6 mm; 1.82 mm
3/4" thread - 16 UNF
Note
Counterhold threaded connection with suitable tool when loosening and tightening.
30 ± 2 Nm
O-ring
10.8 mm; 1.82 mm
Receiver with dryer
Functions
Fig..
Note
Under certain conditions, it is not necessary to renew the receiver with dryer every time that the refrigerant circuit is opened. Information can be found in the workshop information under
“Air conditioning system with refrigerant R134a”
Rep. Gr.
00
“Renewing components”.
O-ring
10.8 mm; 1.82 mm
Refrigerant line
O-ring
10.8 mm; 1.82 mm
High-pressure sender
G65
*
Check with vehicle diagnosis, testing and information system
VAS 5051A in
“guided fault finding” function.
Removing (see the separate procedure)
5/8" thread - 18 UNF
Note
Counterhold threaded connection with suitable tool when loosening and tightening.
16.5 ± 1.6 Nm
O-ring
10.8 mm; 1.82 mm
Air conditioning system magnetic clutch
N25
Repairing (see the separate procedure).
Refrigerant hose
From condenser to receiver with dryer.
O-rings
Low pressure side: 14.3 mm; 2.4 mm.
High pressure side: 10.8 mm; 1.82 mm.
Socket head combi-bolt
22 ± 1 Nm
High-pressure safety valve
Checking
Fig.
Air conditioner compressor
Manufacturer: Sanden, designation: SD6V12.
Removing and installing (see the separate procedure)
Note
If the air conditioner compressor has been exchanged because of internal damage, it is also necessary to purge the refrigerant circuit with refrigerant R134a.
The procedure for purging can be found in the workshop manual
“Air conditioning system with refrigerant R134a VW”
Rep. Gr.
00
, Technical data, Clearing refrigerant circuit of contaminants.
Observe running-in procedures for new air conditioner compressors (see the separate procedure).
Evacuating and charging valve
Low-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing (see the separate procedure)
Capacities (see the separate procedure).
Refrigerant hose
From air conditioner compressor to expansion valve
Bolt
8 Nm
Bolt
8 Nm
O-ring
16.7 mm; 1.82 mm
Expansion valve
In engine compartment on right.
Function and removal (see the separate procedure).
O-ring
14 mm; 1.82 mm
Threaded plate
Seal
Evaporator
In passenger compartment
Removing: remove heater and air conditioning unit (see the separate procedure)
Dismantling and assembling evaporator housing (see the separate procedure).
Functions of receiver with dryer
Note
Under certain conditions, it is not necessary to renew the receiver with dryer every time that the refrigerant circuit is opened. Information can be found in the workshop information under
“Air conditioning system with refrigerant R134a”
Rep. Gr.
00
“Renewing components”.
The receiver collects the liquid droplets and directs them in a continuous stream to the expansion valve. Moisture which has entered the refrigerant circuit during assembly is collected by the dryer in the receiver.
Checking high-pressure safety valve on air conditioner compressor
WARNING
Danger of freezing injuries.
The pressure relief valve releases refrigerant when the engine is running and the pressure in the refrigerant circuit is too high.
Switch off engine.
Task: protects the refrigerant circuit against excessive pressure.
The high-pressure safety valve indicates whether the valve has been opened. An attached adhesive plate (arrow) is pushed out.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other VW procedures
- Renewing refrigerant circuit components
- Renewing refrigerant circuit components, vehicles 03.00 ▸
- Renewing components of refrigerant system, engine codes ANY and AYZ
- Repairing components in refrigerant circuit
- Repairing components of refrigerant circuit of 2nd heater and air conditioning unit “4-C”
- Repairing components of refrigerant circuit, vehicles ▸ 09.00
- Removing engine
- Removing and installing camshaft – VW Golf Cabriolet
- Adjusting valve timing – VW Passat B5
- Removing and installing camshafts – VW Passat B6
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.