Notes:
Refrigerant must be evacuated with Service station V.A.G 1885 first.
The previously used service stations can still be used =>Binder Volkswagen Workshop Equipment.
Safety measures when working on an evacuated refrigerant circuit =>Page
87-3.
All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent the ingress of humidity/moisture.
The colour coding of O-rings for the R134a refrigerant circuits has been discontinued. Coloured and black O-rings are used.
Only the components marked with an * can be replaced without opening and evacuating.
Evaporator
In passenger compartment
Removing => Page
87-73
, Dismantling and assembling housing
Threaded plate
O ring
10.8 mm; 1.85 mm
Heat insulation
O ring
7.6 mm; 1.82 mm
Evacuating and charging valve
High pressure side
Evacuating therefrigerant into the environment is a punishable offence.
Removing and installing => Fig.
2
Capacities => Page
87-84
Refrigerant hose
From compressor to condenser
Hexagon socket head combi-bolt
30 Nm
O ring
14.3 mm; 2.4 mm
Refrigerant hose
From compressor to expansion valve
Compressor
Manufacturer: Sanden
Designation: SD7 - V16
Compressor magnetic coupling -N25-
Manufacturer: Sanden
Carrying out repairs on the magnetic coupling, with the compressor installed, should only be undertaken in exceptional circumstances.
Servicing magnetic coupling with compressor removed => Page
87-40
Pressure relief valve
Checking => Fig.
4
O ring
10.8 mm; 1.82 mm
O-ring
10.8 mm; 1.82 mm
3/4" thread - 16 UNF
35 Nm
Condenser
Removing => Page
87-81
5/8" thread - 18 UNF
15 Nm
O-ring
7.6 mm; 1.82 mm
Foam tube
3/4" thread - 16 UNF
35 Nm
O-ring
10.8 mm; 1.82 mm
High pressure sender -G65-*
Removing and installing:
Removing => Page
87-31
Tightening torque 8 Nm
Renew O ring seal (note Part No.).
The high pressure sender can be removed without evacuating the refrigerant system.
The high pressure sender -G65- supplies information to the radiator fan control unit -J293- and to the engine control unit.
Function:
Switches radiator fan -V7- to next higher speed when pressure increases in refrigerant circuit.
The high pressure sender -G65- can be checked via engine control unit self-diagnosis.
Checking air conditioner high pressure sender -G65- => Page
87-63
Switches off conditioning system when pressure is excessive (for example, insufficient engine cooling).
Switches off conditioning system when pressure is too low (for example, loss of refrigerant).
O-ring
7.6 mm; 1.82 mm
Fluid container with drier
Tasks => Fig.
3
O-ring
10.8 mm; 1.82 mm
5/8" thread - 18 UNF
15 Nm
Refrigerant pipe
Hexagon socket head combi-bolt
7 Nm
Evacuating and charging valve
Low pressure side
Evacuating therefrigerant into the environment is a punishable offence.
Removing and installing => Fig.
1
Capacities => Page
87-84
O-ring
17 mm; 1.85 mm
Bolt
8 Nm
Expansion valve
Engine compartment right
Opening must be sealed sufficiently to stop ingress of water
Removing => Page
87-77
Function
The expansion valve atomizes the instreaming refrigerant and regulates the through flow so that the vapour, depending on temperature, becomes a gas only on reaching the outlet side of the evaporator.
The expansion valves for R134a refrigerant circuits are marked with a green sticker.
O-ring
14 mm; 1.82 mm
Fig.1
Removing evacuating and charging valve, low pressure side
Extract refrigerant circuit with Service station V.A.G 1885 and then renew the valve -3-.
Notes:
Draining the refrigerant into the environment is a punishable offence.
To prevent the ingress of dampness all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
1 -
Connection with external thread and groove for O-ring
2 -
O-ring
7.6 mm; 1.82 mm
3 -
Extraction and filling valve
4 -
O-ring
5 -
Cap
Fig.2
Removing evacuating and charging valve, high pressure side
Extract refrigerant circuit with Service station V.A.G 1885 and then renew the valve -3-.
Notes:
Draining the refrigerant into the environment is a punishable offence.
To prevent the ingress of dampness all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
1 -
Connection with internal thread
2 -
O-ring
10.8 mm; 1.82 mm
3 -
Extraction and filling valve with groove and internal thread for cap.
4 -
O-ring
5 -
Cap
Fig.3
Purpose of the fluid reservoir with drier
The fluid reservoir collects the liquid droplets and guides them in a continuous stream to the expansion valve. Moisture, which has entered the refrigerant circuit during assembly is collected by the dryer in the reservoir.
Fig.4
Checking pressure relief valve on compressor
Task: protects refrigerant circuit against over-pressure
The pressure relief valve tell-tale indicates if valve has opened. An attached adhesive plate -arrow- is pushed out.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other VW procedures
- Renewing refrigerant circuit components, vehicles ▸ 02.00
- Renewing refrigerant circuit components, vehicles 03.00 ▸
- Renewing components of refrigerant system, engine codes ANY and AYZ
- Repairing components in refrigerant circuit
- Repairing components of refrigerant circuit of 2nd heater and air conditioning unit “4-C”
- Repairing components of refrigerant circuit, vehicles ▸ 09.00
- Removing engine
- Removing and installing camshaft – VW Golf Cabriolet
- Adjusting valve timing – VW Passat B5
- Removing and installing camshafts – VW Passat B6
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.