Repairing components in refrigerant circuit
Engine code AGL
Note
The refrigerant must be extracted beforehand, with the air conditioning service station
VAS 6007A.
The previously used service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
Safety measures when working with an extracted refrigerant circuit (see the separate procedure)
. Notes on repair work to vehicles with air conditioning and on handling refrigerant.
Only the components marked with an * can be replaced without opening and evacuating circuit.
To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
The colour coding of O-rings for R134a refrigerant circuits has been discontinued. Coloured and black O-rings are used.
Evaporator
In passenger compartment
Removing (see the separate procedure)
Refrigerant lines
From evaporator to expansion valve
O-ring
14 mm; 2 mm
O-ring
10.6 mm; 2 mm
Expansion valve
In engine compartment on right.
Aperture must be sealed against splashed water.
Removing (see the separate procedure)
Function
The expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
The expansion valves for R134a refrigerant circuits are marked with a green sticker.
Hexagon socket head bolt
5 Nm
O-ring
7.6 mm; 1.8 mm
O-ring
17.2 mm; 1.8 mm
Refrigerant line
From expansion valve to air conditioner compressor.
Hexagon nut
10 Nm
O-ring
10.8 mm; 1.8 mm
Extraction and charging valve
Low-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing
Fig.
Capacities (see the separate procedure)
Protective cap*
Refrigerant line
From receiver with drier to expansion valve.
5/8" thread -18 UNF
17 Nm
O-ring
7.6 mm; 1.8 mm
Receiver/dryer
Under certain conditions, it is no longer necessary to renew the receiver with dryer each time the refrigerant circuit is opened
Rep. Gr.
00
Technical information
“Air conditioning systems - with refrigerant R134a VW”
Renewing parts.
Functions
Fig..
Air conditioning system pressure switch
F129
Removing and installing:
Torque setting 8 Nm
Renew O-ring (note part number)
The pressure switch can be removed without extracting the refrigerant from the refrigerant circuit.
Check air conditioning system pressure switch
F129 (see the separate procedure)
Function:
Switches radiator fan
V7 to next higher speed when pressure increases in refrigerant circuit.
Switches off the air conditioner when the pressure is too high (for example, insufficient engine cooling).
Switches off the air conditioner when the pressure is too low (for example, loss of refrigerant).
Note
At this location, there may be installed a pressure switch with only one instead of two switches
Current flow diagrams, Electrical fault finding and Fitting locations
O-ring
10.8 mm; 1.8 mm
O-ring
7.6 mm; 1.8 mm
5/8" thread -18 UNF
17 Nm
Protective cap*
Extraction and charging valve
High-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing
Fig.
Capacities (see the separate procedure)
O-ring
12.8 mm; 1.8 mm
Refrigerant line
From receiver with drier to condenser.
5/8" thread -18 UNF
17 Nm
O-ring
7.6 mm; 1.8 mm
O-ring
14 mm; 1.8 mm
Condenser
Removing (see the separate procedure)
Hexagon combi-bolt
7/8" thread -14 UNF
30 Nm
Refrigerant hose
From air conditioner compressor to condenser.
O-ring
14.3 mm; 2.4 mm
Air conditioning system magnetic clutch
N25
Manufacturer: Sanden
Repairs to the magnetic clutch with the air conditioner compressor installed should only be performed only as an exception.
Repairing magnetic coupling with compressor removed (see the separate procedure)
Air conditioner compressor
With air conditioning system magnetic clutch
N25.
Manufacturer: Sanden
Overview - air conditioner compressor manufacturers (see the separate procedure)
High-pressure safety valve
Checking (see the separate procedure)
O-ring
10.8 mm; 1.8 mm
Socket head screw
20 Nm
Refrigerant line
From expansion valve to air conditioner compressor.
Socket head screw
20 Nm
Hexagon socket head bolt
5 Nm
O-ring
10.8 mm; 1.8 mm
O-ring
14 mm; 1.8 mm
Engine code AGL
Evaporator
In passenger compartment
Removing (see the separate procedure)
Refrigerant lines
From evaporator to expansion valve
O-ring
14 mm; 2 mm
O-ring
10.6 mm; 2 mm
Expansion valve
In engine compartment on right.
Aperture must be sealed against splashed water.
Removing (see the separate procedure)
Function
The expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
The expansion valves for R134a refrigerant circuits are marked with a green sticker.
Hexagon socket head bolt
5 Nm
O-ring
7.6 mm; 1.8 mm
O-ring
17.2 mm; 1.8 mm
Refrigerant line
From expansion valve to air conditioner compressor.
Hexagon nut
10 Nm
O-ring
10.8 mm; 1.8 mm
Extraction and charging valve
Low-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing
Fig.
Capacities (see the separate procedure)
Protective cap*
Refrigerant line
From receiver with drier to expansion valve.
5/8" thread -18 UNF
15 Nm
O-ring
7.6 mm; 1.8 mm
Receiver/dryer
Under certain conditions, it is no longer necessary to renew the receiver with dryer each time the refrigerant circuit is opened
Rep. Gr.
00
Technical information
“Air conditioning systems - with refrigerant R134a VW”
Renewing parts.
Functions
Fig..
Air conditioning system pressure switch
F129
Removing and installing:
Torque setting 8 Nm
Renew O-ring (note part number)
The pressure switch can be removed without extracting the refrigerant from the refrigerant circuit.
Check air conditioning system pressure switch
F129 (see the separate procedure)
Function:
Switches radiator fan
V7 to next higher speed when pressure increases in refrigerant circuit.
Switches off the air conditioner when the pressure is too high (for example, insufficient engine cooling).
Switches off the air conditioner when the pressure is too low (for example, loss of refrigerant).
Note
At this location, there may be installed a pressure switch with only one instead of two switches
Current flow diagrams, Electrical fault finding and Fitting locations
O-ring
10.8 mm; 1.8 mm
O-ring
7.6 mm; 1.8 mm
5/8" thread -18 UNF
15 Nm
Protective cap*
Extraction and charging valve
High-pressure side
Releasing refrigerant into the environment is a punishable offence.
Removing and installing
Fig.
Capacities (see the separate procedure)
O-ring
12.8 mm; 1.8 mm
Refrigerant line
From receiver with drier to condenser.
5/8" thread -18 UNF
15 Nm
O-ring
7.6 mm; 1.8 mm
Condenser
Removing (see the separate procedure)
Radiator fan
V7
Secured to condenser with 3 bolts
Hexagon combi-bolt
Radiator
7/8" thread -14 UNF
30 Nm
O-ring
14 mm; 1.8 mm
Refrigerant hose
From air conditioner compressor to condenser.
Socket head screw
20 Nm
O-ring
11.1 mm; 1.8 mm
Socket head screw
20 Nm
High-pressure safety valve
Checking (see the separate procedure)
Air conditioning system magnetic clutch
N25
Manufacturer: Denso
Repairs to the magnetic clutch with the air conditioner compressor installed should only be performed only as an exception.
Repairing air conditioning system magnetic clutch
N25 with the air conditioner compressor removed (see the separate procedure)
Air conditioner compressor
With air conditioning system magnetic clutch
N25.
Manufacturer: Denso
Overview - air conditioner compressor manufacturers (see the separate procedure)
O-ring
23.8 mm; 2.4 mm
Socket head screw
20 Nm
Hexagon socket head bolt
5 Nm
O-ring
10.8 mm; 1.8 mm
O-ring
14 mm; 1.8 mm
Removing extraction and charging valves, high and low-pressure sides
WARNING
Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant may escape.
Extract refrigerant before opening refrigerant circuit.
Extract refrigerant from refrigerant circuit using air conditioning service station
VAS 6007A and only then renew valves.
For additional service stations ⇒ V.A.G Workshop Equipment Catalogue.
Note
Releasing refrigerant into the environment is a punishable offence.
All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.
O-ring; 12.8 mm; 1.8 mm
High-pressure valve
Cap for high-pressure valve
Cap for low-pressure valve
Low-pressure valve
O-ring; 10.8 mm; 1.8 mm
When installing valves, moisten seals with oil and insert in grooves (arrow) of valves.
Functions of receiver with dryer
The receiver collects the liquid droplets and directs them in a continuous stream to the expansion valve. Moisture which has entered the refrigerant circuit during assembly is collected by the dryer in the receiver.
Note
Under certain conditions, it is no longer necessary to renew the receiver with dryer each time the refrigerant circuit is opened
Rep. Gr.
00
Technical information
“Air conditioning systems - with refrigerant R134a VW”
Renewing parts.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other VW procedures
- Repairing components of refrigerant circuit of 2nd heater and air conditioning unit “4-C”
- Repairing components of refrigerant circuit, vehicles ▸ 09.00
- Repairing components of refrigerant circuit, vehicles 10.00 ▸
- Repairing refrigerant circuit components
- Renewing refrigerant circuit components
- Renewing refrigerant circuit components, vehicles ▸ 02.00
- Removing engine
- Removing and installing camshaft – VW Golf Cabriolet
- Adjusting valve timing – VW Passat B5
- Removing and installing camshafts – VW Passat B6
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.