🧭 Before you start

Models recorded for this source: VW Passat CC (357, 2008–2012), VW Passat B7 saloon (362, 2010–2014), VW Passat B7 Variant (365, 2010–2014)

Don't miss

  • Fit delivery module into reducing agent tank, noting markings (A). The marks (A) must align when inserting.
  • Carefully reach into cup of delivery module and engage it by turning clockwise. The marks (B) must align when engaged correctly.
  • Moisten sealing web of cover with water and carefully push into gasket. The marks (1) must align.

🔧 Engine codes recorded for this source

📋 Procedure

  1. ⚠ The reducing agent can irritate skin, eyes and respiratory organs. After skin contact with this agent, wash immediately with plenty of water. If necessary, call a doctor. — Remove reducing agent tank (see the separate procedure).
  2. Remove upper part of insulation (see the separate procedure).
  1. ⚠ Protect separated electrical connections against wetting with a reducing agent by suitable means, e.g. plastic bag and cable ties. Electrical connections may be damaged due to the high penetration ability along with subsequent crystallisation of the reducing agent. — Unplug connectors (arrows) at pump for reducing agent V437.
  2. First press securing clip for line connection together in direction of (arrow 1) as shown, and pull off delivery line in direction of (arrow 2) without tools and without »jerking«.
  1. ⚠ Immediately seal all openings and connections using suitable plugs to stop ingress of dirt. The smallest particle of dirt can cause extensive damage to the system. Protect separated electrical connections against wetting with a reducing agent by suitable means, e.g. plastic bag and cable ties. Electrical connections may be damaged due to the high penetration ability along with subsequent crystallisation of the reducing agent. — Disconnect connectors (2) and (3), unscrew securing bolts (A) and remove pump for reducing agent V437 upwards.
  2. Cut cable ties (arrows) at locking ring and pull off breather line (1) upwards.
  3. Place special wrench T50014 onto locking ring as shown and unscrew.
  1. ⚠ When open, only tilt cover a max. of 30° this prevents damage to electrical cables and suction probe of delivery module. — Open cover of delivery module, using removing wedge 3409 if necessary.
  2. Carefully reach into cup of delivery module and release it from its locked position by turning anticlockwise.
  3. Remove delivery module upwards out of reducing agent tank.
  1. Place gasket into opening in reducing agent tank.
  2. Fit delivery module into reducing agent tank, noting markings (A). The marks (A) must align when inserting.
  3. Carefully reach into cup of delivery module and engage it by turning clockwise. The marks (B) must align when engaged correctly.
  4. Moisten sealing web of cover with water and carefully push into gasket. The marks (1) must align.
  5. Start locking ring and tighten until finger-tight.
  1. ⚠ Ensure sealing ring is not cross-threaded on threads of tank for reducing agent. If the sealing ring does not sit properly, the consequence will be leaks and considerable corrosion damage. — Place special wrench T50014 onto locking ring as shown and tighten. Specified torque (value given in the factory table, not available here).
  2. Wash away any leaked reducing agent with water.
  3. Attach cable ties (arrows) to locking ring and connect breather line (1).
  4. Locate pump for reducing agent V437, attach connectors (2) and (3) and tighten securing bolts (A). Specified torque (value given in the factory table, not available here).
  5. Attach connectors (arrows) to pump for reducing agent V437 and connect delivery line (1).
  6. Set upper part of insulation in position (see the separate procedure).
  7. Install reducing agent tank (see the separate procedure).
  8. Check for leaks: Guided functions.

📐 6 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 6 workshop diagrams for this job Ask about your VW CFFA — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.