📋 Procedure

Battery voltage OK.
Fuse No. 18 OK.

▸ 07.92

Briefly operate starter. Fuel pump(s) must be heard to run briefly
-approx. 1 second-

08.92 ▸

Switch on ignition.

Fuel pump must be heard to run briefly.

If the fuel pump(s) do not run:

Switch off ignition.

Pull the fuel pump relay (J17) out of relay plate (relay position 12).

Notes:

If tools are necessary to pull relays or control units out of the relay plate, first disconnect battery earth strap.
Before disconnecting battery earth strap obtain code for radios with anti-theft coding.

Connect remote control V.A.G 1348/3A with adapter cable V.A.G 1348/3-2 to contact 4 and battery positive (+).
Operate remote control.

Fuel pump(s) run:

Check activation of fuel pump relay:

=> Repair group 01; Electrical check; wiring and component check with test box V.A.G 1598
4-Cyl. injection engine (G charger), Mechanics
Electrical check wiring and component check with test box V.A.G 1598

Fuel pumps do not run or only one pump runs:

Vehicles with lift pump:

Connect diode test lamp V.A.G 1527 with aux. cables from V.A.G 1594 to the fuel pump/lift pump connector (red/yellow and brown wire).

Vehicles without lift pump:

Connect diode test lamp V.A.G 1527 with aux. cables from V.A.G 1594 to the outer contacts of the connector.

Continued for all vehicles:

Operate remote control.
LED must light up

LED does not light up:

Locate and eliminate open circuit using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

LED lights up (voltage supply OK.):

Vehicles with lift pump:

Renew fuel pump or lift pump.

Remove union nut with 3217.
Check that the electrical wires between flange and fuel pump are connected.

If not open circuit can be found:

Renew fuel pump/fuel delivery unit.

Checking delivery rate

Voltage supply OK.
Remote control V.A.G 1348/3A connected.

Remove fuel tank cap.

Lift pump ▸09.89

Pull off fuel supply pipe -1- (black) and seal.
Connect a max. 350 mm long hose to free connection on sender.
Hold hose in a measuring container and operate remote control for
10 seconds
In this time min. 300 cm3 of fuel must be delivered.

Fuel pump

Lift pump OK.

Pull fuel supply pipe -1- off fuel manifold.
Connect pressure gauge V.A.G 1318 with adapter 1318/10 to the fuel supply pipe -1- .
Connect hose V.A.G 1318/1 to adapter V.A.G 1318/11 on pressure gauge and hold in a measuring container.
Open pressure gauge cut-off tap (lever in throughflow direction).
Operate the remote control V.A.G 1348/3A and slowly close the cut-off tap, until the gauge shows following pressure:
▸09.89: 3 bar.
(Fuel pump in pump reservoir)
10.89 ▸: 4 bar (Fuel pump in fuel tank)
From this point do not alter the position of the cut-off tap.
Empty measuring container.
Operate remote control for
30 seconds.
Compare amount of fuel delivered with specification.

Graph for fuel pump in pump reservoir

*)
Minimum delivery cm3/30 seconds

**)
Voltage at fuel pump with engine stopped and pump running (approx. 2 volts less than battery voltage).

Graph for fuel pump in fuel tank

*)
Minimum delivery cm3/30 seconds

**)
Voltage at fuel pump with engine stopped and pump running (approx. 2 volts less than battery voltage).

If the minimum delivery rate is not attained:

Fuel pipes kinked or blocked.
Fuel filter blocked.
Fuel pump defective, renew fuel pump/fuel delivery unit.

Checking fuel pump non-return valve

Remote control V.A.G 1348/3A connected
Pressure gauge V.A.G 1318 connected

Note:

With this check the fuel supply pipe connections from the fuel pump to the point at which the pressure gauge V.A.G 1318 is connected will be checked for leaks at the same time.

Close pressure gauge cut-off tap (lever at right angles to throughflow direction).
Separate remote control at short intervals, until a pressure of
Approx. 3 bar has built up.
If pressure builds up too high, lower excess pressure by carefully opening the cut-off tap.

Warning!
Danger of spray when opening the shut-offtap, hold container over the free connection of the pressure gauge.
Watch pressure drop. After 10 minutes the pressure must not drop below 2 bar
If necessary check pipe connections for leaks and/or renew fuel pump/fuel delivery unit.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.