Removing and installing Lambda probes (before catalytic converter): Audi A8 D3 (4E) (BFL, BFM, BGK)
Removing and installing Lambda probes (before catalytic converter) — Audi A8 D3 (4E) (BFL, BFM, BGK). Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A8 D3 (4E, 2002–2010)
- Replacement notes from the steps (read the conditions below): Remove securing bolts (1) to renew gaskets for intake manifold.
Don't miss
- The intake manifold must first be removed before the Lambda probes before catalytic converter can be removed.
- Engines with code letters BGK have no fuel return pipe.
- The illustration is only an example (shows 3.7 ltr. BFL engine).
- Seal intake ports on cylinder heads with clean cloths.
📋 Procedure
- Remove engine cover. [Note: The intake manifold must first be removed before the Lambda probes before catalytic converter can be removed.]
- Remove intake hose between air cleaner and throttle valve module.
- Open the fuel supply pipe and fuel return pipe (1 and 2). [Note: Engines with code letters BGK have no fuel return pipe.]
- Pull vacuum hose (arrow) off fuel pressure regulator (does not apply to engine code letters BGK).
- Detach reservoir (1) and hose (2) from throttle valve module.
- Detach electrical connector from secondary air inlet valve and from throttle valve module.
- Unscrew bracket from secondary air inlet valve.
- Remove connecting hose for crankcase breather.
- Disconnect vacuum hose (1) for intake manifold change-over at intake manifold.
- Disconnect vacuum hose at T-connection (2). [Note: The illustration is only an example (shows 3.7 ltr. BFL engine).]
- Pull off connectors from intake-manifold changeover valves.
- Unplug connectors from Hall sender (bank 1) and from solenoid valve for variable valve timing (bank 2).
- Unplug all 8 electrical connectors from injectors.
- Move both connector rails to side.
- Unscrew all hexagon socket bolts from intake manifold.
- Carefully remove intake manifold upwards. The water connection on the throttle valve module remains connected.
- Place the intake manifold aside (take care with water connection). [Note: Seal intake ports on cylinder heads with clean cloths.]
- Unplug the corresponding Lambda probe connector.
- Release all cable ties to move electrical wiring clear.
- Unscrew the corresponding Lambda probe using tool from Lambda probe open ring spanner set 3337 (illustration shows Lambda probe 2G108 on bank 2). [Note: Threads of new Lambda probes are already coated with assembly paste; the paste must not get into the slots on the probe body. In the case of a used Lambda probe grease only the thread with high-temperature paste. The paste must not get into the slots on the probe body. High-temperature paste Parts catalogueUse a silicone-free lubricant when installing the intake hose. When installing, the Lambda probe wire must always be reattached at the same locations to prevent it from coming into contact with the exhaust pipe.] [Note: Renew seals and gaskets. All cable ties which are released or cut open when removing must be fitted in the same position when installing. Re-secure all hose connections using genuine hose clips (same as original equipment). Parts catalogue]
- Remove securing bolts (1) to renew gaskets for intake manifold.
- Observe locating pin (2) when fitting intake manifold.
- Tighten bolts on intake manifold in stages and in diagonal sequence.
- Check fuel system for leaks (see the separate procedure).
📐 11 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking ageing of lambda probes before catalytic converter (on vehicles which conform to emission standard EU III)
- Checking Lambda probes and Lambda control before catalytic converter
- Testing lambda probe heating -Z19 and -Z29 at lambda probes (before and after catalytic converter)
- Checking ageing of lambda probes -G39 and -G108 upstream of catalytic converter
- Checking lambda control and lambda probes -G130 and -G131 downstream of catalytic converter
- Checking lambda control and lambda probes -G39 and -G108 upstream of catalytic converter
- Removing and installing kickdown switch F8 – Audi A8 D3
- Removing and installing oil level and oil temperature sender G266.
- Removing and installing roller rocker fingers – Audi A3
- Removing and installing accelerator pedal module with accelerator position sender
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.