Special tools and workshop equipment required
V.A.G 1526 A
V.A.G 1594 A
V.A.G 1598/31
V.A.G 1788/10
VAS 5051 with VAS 5051/1
or
V.A.G 1551 with V.A.G 1551/3 A
Note:
The lambda probe upstream of the catalytic converter (bank 1, probe 1 or bank 2, probe 1) effects regulation to lambda = 1. Contamination or overheating of this lambda probe for example may produce a shift in the control value. Any deviations from lambda = 1 are detected by the lambda probe downstream of the catalytic converter (bank 1, probe 2 or bank 2, probe 2). On recognising downward or upward deviations, it correspondingly influences control action upstream of the catalytic converter, so as to produce an appropriate increase or reduction.
Test requirements:
No leaks in exhaust system
Coolant temperature at least 80 °C=>Display group 004, display zone 3
Engine idling
Ageing of lambda probes upstream of catalytic converter checked =>Page
24-157
Test sequence
Connect up vehicle diagnostic, testing and information system VAS 5051=>Page
01-7 and select vehicle system "01 - Engine electronics" from list. Engine must be idling.
Indicated on VAS 5051:
From list -1- select diagnostic function "04 - Basic setting".
Indicated on VAS 5051:
1 -
Enter display group
Use keypad -2- to enter "030" for "Display group number 030" and confirm by touching Q key.
Indicated on VAS 5051:
Activate basic setting by touching key -A-.
Check display in zones -2- and -4-.
Notes:
Specifications are obtained faster by increasing engine speed.
"Lambda probe status" indicates status of lambda control and lambda probes.
Display zones
1 · 2 · 3 · 4
Display group 030: Lambda status at idle
Display · X X X · X X X · X X X · X X X
Significance · Lambda probe status bank 1, probe 1 · Lambda probe status / bank 1, probe 2 · Lambda probe status bank 2, probe 1 · Lambda probe status / bank 2, probe 2
Operating range · 0 = off / 1 = on · 0 = off / 1 = on · 0 = off / 1 = on · 0 = off / 1 = on
Specification · X X 1 1 1 · X 1 1 0 · X X 1 1 1 · X 1 1 0
Note · Explanatory notes on display => Page 24-177
Notes:
Only the last three positions on the right in the five-position display (in zones 1 and 3) or the four-position display (in zones 2 and 4) are relevant.
Control function of lambda probe downstream of catalytic converter (bank 1, probe 2 and bank 2, probe 2) is not active if there is no engine load.
First position in 3-position display (heating) fluctuates between 0 and 1.
Third position in 3-position display (lambda control) fluctuates between 0 and 1.
Explanatory notes on 3-position display in display group 30
Note:
Only the last three positions on the right in the five-position display (in zones 1 and 3) or the four-position display (in zones 2 and 4) are relevant.
1 · 1 · 1 · Display zones 1 to 4
X · Lambda control / 0 = not active / 1 = active
X · Lambda probe condition / 0 = not active / 1 = active
X · Status of lambda probe heating / 0 = not active / 1 = active
Indicated on VAS 5051:
Do not continue with test until display in zones -2- and -4- has reached "110" at least once.
Touch ◂ key.
Checking lambda control downstream of catalytic converter
Indicated on VAS 5051:
1 -
Enter display group
Use keypad -2- to enter "037" for "Display group number 037" and confirm by touching Q key.
Indicated on VAS 5051:
Activate basic setting by touching key -A-.
Check dwell time between lambda probe 1 upstream of catalytic converter and lambda probe 2 downstream of catalytic converter in display zone 3 and diagnostic result in display zone 4.
Display zones
1 · 2 · 3 · 4
Display group 037: Diagnosis of lambda control system (bank 1)
Display · xxx % · x.xxx V · xxx ms · Test ON
Significance · Engine load · Voltage of lambda probe downstream of catalytic converter, bank 1 · Lambda correction value between lambda probes 1 and 2; bank 1 · Diagnosis status
Operating range · 15...150 % · 0.000...1.000 V · -1200...1200 ms · Test OFF / Test ON / Syst. OK / Syst. n.OK
Specification · 14...24 % · 0.000...1.000 V · -200...200 ms · Syst. OK
Note · If reading does not match specification: Evaluation of display zone 2 / => Page 24-175 · If reading does not match specification: Continuation / => Page 24-176 · If "Syst. not OK" is displayed: Interrogate fault memory => Page 24-176
Note on display zone 3:
Lambda control downstream of catalytic converter is higher-ranking than lambda control upstream of catalytic converter and acts as setpoint control. It corrects minor lambda probe upstream of catalytic converter shifts to rich or lean by holding lambda control upstream of catalytic converter on upper/lower stop for a certain period (dwell time). If the time is in the positive range (e.g. 50 ms) the mixture is enriched. If the time is in the negative range (e.g. -50 ms) the mixture is leaned.
Touch ◂ key.
Indicated on VAS 5051:
1 -
Enter display group
Use keypad -2- to enter "038" for "Display group number 38" and confirm by touching Q key.
Indicated on VAS 5051:
Activate basic setting by touching key -A-.
Check dwell time between lambda probe 1 upstream of catalytic converter and lambda probe 2 downstream of catalytic converter in display zone 3 and diagnostic result in display zone 4.
Display zones
1 · 2 · 3 · 4
Display group 038: Diagnosis of lambda control system (bank 2)
Display · xxx % · x.xxx V · xxx ms · Test ON
Significance · Engine load · Voltage of lambda probe downstream of catalytic converter, bank 2 · Lambda correction value between lambda probes 1 and 2; bank 2 · Diagnosis status
Operating range · 15...150 % · 0.000...1.000 V · -1200...1200 ms · Test OFF / Test ON / Syst. OK / Syst. n.OK
Specification · 14...24 % · 0.000...1.000 V · -200...200 ms · Syst. OK
Note · If reading does not match specification: Evaluation of display zone 2 / => Page 24-175 · If reading does not match specification: Continuation / => Page 24-176 · If "Syst. not OK" is displayed: Interrogate fault memory => Page 24-176
Note on display zone 3:
Lambda control downstream of catalytic converter is higher-ranking than lambda control upstream of catalytic converter and acts as setpoint control. It corrects minor lambda probe upstream of catalytic converter shifts to rich or lean by holding lambda control upstream of catalytic converter on upper/lower stop for a certain period (dwell time). If the time is in the positive range (e.g. 50 ms) the mixture is enriched. If the time is in the negative range (e.g. -50 ms) the mixture is leaned.
Evaluation of display groups 037 and 038
Display group: 37/38
Display zone: 2 · Possible cause of trouble · Fault remedy approx. 0.450 V · - Open circuit in wire 4 between lambda probe and control unit · - Check signal wire and actuation / => Page 24-182
- Open circuit in wire 3 between lambda probe and control unit
- Lambda probe heating defective / - Lambda probe defective · - Check lambda probe heating / => Page 24-177 / Replace lambda probe
Greater than 1.100 V · - Short to positive in wire 4 between lambda probe and control unit · - Check lambda probe wiring, bank 1 probe 2 (downstream of catalytic converter) => Page 24-186
Less than 0.100 V · - Short to earth in wire 4 between lambda probe and control unit / - Short circuit between wires 3 and 4 · - Check lambda probe wiring, bank 2 probe 2 (downstream of catalytic converter) => Page 24-191
Continuation
If reading does not match specification in display zones 3 or 4:
Locate leakage air at exhaust or catalytic converter (check screw-type clamps and exhaust for damage).
Replace relevant lambda probe "upstream of" catalytic converter.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking lambda control and lambda probe -G130 and -G131 downstream of catalytic converter
- Checking lambda probe heating for lambda probes upstream or downstream of catalytic converter
- Removing and installing Lambda probe after catalytic converter G130/G131/G287/G288
- Checking ageing of lambda probes before catalytic converter (on vehicles which conform to emission standard EU III)
- Checking ageing of lambda probes -G39 and -G108 upstream of catalytic converter
- Checking lambda control and lambda probes -G39 and -G108 upstream of catalytic converter
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.