TorqFix

Removing and installing expansion valve (front): Audi Q7 (4M)

Removing and installing expansion valve (front) — Audi Q7 (4M). 21 source steps. Check the document conditions against your vehicle.

21 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi Q7 (4M, 2015–)

  • Opens: refrigerant (A/C)
  • Replacement notes from the steps (read the conditions below): Renew O-rings (B) and (F); for correct version refer to Electronic parts catalogue.
  • Also covered elsewhere: Electronic parts catalogue

Don't miss

  • Remove refrigerant lines (A, B) from the front expansion valve and place to one side (do not remove) Detaching and re-attaching refrigerant lines from front expansion valve.
  • Seal off open connections in the lines at the connection point using clean plugs, e.g. from engine bung setVAS 6122.
  • Make sure that the support ring (D) is correctly positioned and check the grommet in the back wall of the plenum chamber for damage and proper installation.
  • Lubricate O-rings lightly with refrigerant oil before installing Refrigerant circuit seals.
  • There are different versions of the expansion valve (A) (identical housing but different characteristic control curve); therefore it is important to observe the correct assignment Electronic parts catalogue.

📋 Procedure

  1. Switch off ignition.
  2. Discharge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  3. Remove strut bar (D)Running gear, axles, steering 40. Spring strut, axle strut (top); Removing and installing strut bar.
  4. Detach bottom plenum chamber bulkhead (E) from vehicle and move to one side (do not remove) General body repairs, exterior 50. Bulkhead; Exploded view - bulkhead.
  5. Remove refrigerant lines (A, B) from the front expansion valve and place to one side (do not remove) Detaching and re-attaching refrigerant lines from front expansion valve.
  6. Remove bolts (A).
  7. Detach expansion valve (B) from refrigerant lines to evaporator. [Note: Seal off open connections in the lines at the connection point using clean plugs, e.g. from engine bung set VAS 6122.]
  1. Make sure that the support ring (D) is correctly positioned and check the grommet in the back wall of the plenum chamber for damage and proper installation.
  2. Clean connecting pipes (B) and (C) leading to the evaporator and check for damage.
  3. Check retaining plate (D) on connecting pipes (B) and (C) for proper attachment to the connecting pipes leading to the evaporator.
  4. Replace the O-rings (E) and (F); for correct version, refer to Electronic parts catalogue [Note: Observe fitting instructions for O-rings Refrigerant circuit seals. Retaining plate (A) must be inserted in the mountings in connecting pipes (B) and (C).O-rings (D) and (E) are inserted in the grooves on connecting pipes (B) and (C)(arrows).]
  1. Lubricate O-rings lightly with refrigerant oil before installing Refrigerant circuit seals.
  2. Check the connections on expansion valve (A) (to connecting pipes (C) and (E)) leading to the evaporator and check for damage. [Note: There are different versions of the expansion valve (A) (identical housing but different characteristic control curve); therefore it is important to observe the correct assignment Electronic parts catalogue.]
  1. Renew O-rings (B) and (F); for correct version refer to Electronic parts catalogue.
  2. Pay attention to correct positioning of the mounting plate (D) on the connecting pipes (C) and (E) to the evaporator.
  3. Tighten bolts (G).
  1. Attach the refrigerant line to the expansion valve Detaching and re-attaching refrigerant lines from front expansion valve.
  2. Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  3. Re-install remaining components (removed earlier).
  4. Interrogate the event memory of the front air conditioner operating and display unit E87 and erase any faults displayed in "“Guided Fault Finding”" mode.
  5. Start up air conditioner after charging refrigerant circuit Starting up air conditioner after charging refrigerant circuit. [Note: Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134a 87. General notes on air conditioning systems.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.