Models recorded for this source: Audi A8 D4 (4H, 2010–2017)

  • Opens: refrigerant (A/C)
  • Also covered elsewhere: Electronic parts catalogue

Don't miss

  • Seal open pipes and connections at refrigerant line with suitable caps (to prevent ingress of dirt and moisture).
  • The front wall of the plenum chamber (A) is attached using plastic nuts (B), expanding rivets (C) and bolts (D).
  • This illustration shows the connections to the evaporator with the expansion valve removed.
  • Lubricate O-rings lightly with refrigerant oil before installing Refrigerant circuit seals.
  • Make sure the O-rings are correctly positioned in the grooves of the refrigerant line connections at the refrigerant lines (B) and (C).

📋 Procedure

  1. Switch off ignition.
  2. Discharge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit. [Note: Seal open pipes and connections at refrigerant line with suitable caps (to prevent ingress of dirt and moisture).]
  1. Remove plenum chamber cover (A)General body repairs, exterior 50. Bulkhead; Removing and installing plenum chamber cover. [Note: The plenum chamber cover (A) must be undamaged in order to prevent water from running into the air conditioning unit via the intake duct (C) when the plenum chamber cover (A) is fitted. The plenum chamber cover (A) must also be properly and fully engaged in the frame (D) of the windscreen (B).]
  1. Detach wiring harness (A) and move to side.
  2. If fitted, remove strut bar (B)Running gear, axles, steering 40. Spring strut, axle strut (top); Removing and installing strut bar
  3. Detach or remove engine control unit (C) and remove corresponding brackets 23Engine control unit or 24Engine control unit.
  4. Remove plenum chamber partition panel (A)General body repairs, exterior 50. Bulkhead; Exploded view - bulkhead. [Note: The front wall of the plenum chamber (A) is attached using plastic nuts (B), expanding rivets (C) and bolts (D).]
  1. Remove bolts (A).
  2. Detach the refrigerant lines (B) and (C) from the expansion valve (J). [Note: Seal open connections at refrigerant line and expansion valve with suitable caps (to prevent ingress of dirt and moisture).On vehicles with a high-voltage system, remove the refrigerant line from the shut-off valve 1 for refrigerant of hybrid battery if necessary .To remove the refrigerant line, unscrew the union nut (4) whilst providing support at the shut-off valve 1 (Item 3).]
  1. Make sure that the support ring (E) is correctly positioned and check the socket in the back wall of the plenum chamber for damage and proper installation. [Note: This illustration shows the connections to the evaporator with the expansion valve removed.]
  1. Thoroughly clean all the connections in the expansion valve (J) and at the refrigerant lines (B) and (C) and check for damage.
  2. Renew O-rings (D) and (E); for correct version, refer to Electronic parts catalogue. [Note: Observe fitting instructions for O-rings Refrigerant circuit seals. On vehicles with high-voltage system (hybrid vehicles with battery cooling module), the refrigerant line (C) is fitted with the refrigerant shut-off valve 1 for hybrid battery N516.]
  1. Lubricate O-rings lightly with refrigerant oil before installing Refrigerant circuit seals.
  2. Make sure the O-rings are correctly positioned in the grooves of the refrigerant line connections at the refrigerant lines (B) and (C).
  3. Fit the bolts (A) for the refrigerant lines (B) and (C).
  1. Following attachment, check the routing of the refrigerant lines. Ensure strain-free insertion in the holders provided and make sure the lines do not come into contact with other components.
  2. Install plenum chamber partition panel General body repairs, exterior 50. Bulkhead; Exploded view - bulkhead.
  3. Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  4. Re-install remaining components (removed earlier).
  5. Interrogate the event recorder of the front air conditioner operating and display unit, Climatronic control unit J255 and erase any faults displayed in "“Guided Fault Finding”" mode.
  6. Start up air conditioner after charging refrigerant circuit Starting up air conditioner after charging refrigerant circuit. [Note: Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134a 87. General information on air conditioner.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.