TorqFix

Removing and installing exhaust gas recirculation control motor V338: engine codes CAMA, CAMB, CAPA — Audi

Removing and installing exhaust gas recirculation control motor V338 — engine codes CAMA, CAMB… Read available instructions and vehicle application notes.

15 steps 8 engine codes

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A5 (8T, 2007–2016), Audi A5 Cabriolet (8F), Audi A4 B8 (8K, 2007–2015)

  • Opens: coolant
  • Replacement notes from the steps (read the conditions below): Remove bolts (1, 2, 3), detach exhaust gas recirculation control motorV338 and detach from coolant hose (4). [Note: Renew seals and gaskets.]

Don't miss

  • Disregard (arrow) on right-side of illustration.
  • Disregard (item 2).
  • Disregard (item 1).
  • Renew seals and gaskets.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Drain coolant (see the separate procedure).
  2. Remove engine cover panel (arrows).
  1. Unscrew bolt (left arrow) and remove retaining clip.
  2. Unscrew union nuts (1 ... 4) and detach high-pressure pipes. [Note: Disregard (arrow) on right-side of illustration.]
  1. Remove union nuts (1) and (3), move high-pressure pipe clear and remove. [Note: Disregard (item 2).]
  1. Remove intake manifold (top section) (see the separate procedure).
  2. Remove oil filter housing (see the separate procedure).
  3. Pull out retaining clip and detach connection (arrow) with thermostat for exhaust gas recirculation.
  4. Detach electrical connector (2) for exhaust gas recirculation temperature sensor G98 from bracket and unplug. [Note: Disregard (item 1).]
  1. Unplug electrical connector (arrow) for exhaust gas recirculation control motor V338.
  2. Remove bolts (1, 2, 3), detach exhaust gas recirculation control motor V338 and detach from coolant hose (4). [Note: Renew seals and gaskets.]
  1. Install oil filter housing (see the separate procedure).
  2. Install intake manifold (top section) (see the separate procedure).
  3. Install high-pressure pipes (see the separate procedure).
  4. Fill up with coolant (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.