TorqFix

Removing and installing exhaust gas recirculation cooler: engine codes CCLA, CCWA, CCWB, CGKA, CGKB — Audi

Removing and installing exhaust gas recirculation cooler — engine codes CCLA, CCWA, CCWB, CGKA… Read available instructions and vehicle application notes.

25 steps 8 engine codes

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A5 (8T, 2007–2016), Audi A5 Cabriolet (8F), Audi A4 B8 (8K, 2007–2015)

  • Opens: coolant
  • Replacement notes from the steps (read the conditions below): Remove bolts (arrows) and lift off exhaust gas recirculation cooler from cylinder block. [Note: Renew gaskets and O-rings. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue.]

Don't miss

  • Disregard (item 2).
  • Disregard (item 1).
  • Renew gaskets and O-rings. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Drain coolant (see the separate procedure).
  2. Remove particulate filter (see the separate procedure).
  3. Remove coolant pipe (top left): engine codes CCWA, CCWB, CGKA, CGKB , vehicles with SCR catalytic converter (see the separate procedure).
  4. Remove coolant pipe (top right) (see the separate procedure).
  5. Remove oil filter housing (see the separate procedure).
  6. Release clamp (arrow) and detach exhaust gas recirculation pipe (1).
  7. Remove bolt (1) and banjo bolt (3) and move oil supply line clear to one side. [Note: Disregard (item 2).]
  1. Remove bolts (arrows) and (1).
  2. Detach electrical connector (2) (orange) for exhaust gas recirculation temperature sensor G98 from bracket and unplug. [Note: Disregard (item 1).]
  1. Remove banjo bolt (1) and bolt (2) and move coolant pipe clear to one side.
  2. Unplug electrical connector (1).
  3. Carefully press linkage (2) off ball stud (arrow).
  4. Remove bolts (3) and detach intake manifold flap motor 2V275(item 4).
  5. Perform the same work steps on the other side of the vehicle.
  6. Disconnect vacuum hose (1).
  7. Lift retaining clip (2) and disconnect coolant hose.
  8. Release hose clip (3) and detach coolant hose.
  9. Remove bolts (arrows) and lift off exhaust gas recirculation cooler from cylinder block. [Note: Renew gaskets and O-rings. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue.]
  1. Install intake manifold flap motors (see the separate procedure).
  2. Install coolant pipe (see the separate procedure).
  3. Install oil filter housing (see the separate procedure).
  4. Install coolant pipe (top right) (see the separate procedure).
  5. Install coolant pipe (top left): engine codes CCWA, CCWB, CGKA, CGKB , vehicles with SCR catalytic converter (see the separate procedure).
  6. Install particulate filter (see the separate procedure).
  7. Fill up with coolant (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.