Checking secondary air pump relay J299 and secondary air pump motor V101: Audi A6 C5 (4B) (ASN, AVK, BBJ)
Checking secondary air pump relay J299 and secondary air pump motor V101 — Audi A6 C5 (4B) (ASN… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A6 C5 (4B)
- Special tools named: VAS 5051/1
- Replacement notes from the steps (read the conditions below): Renew secondary air pump relayJ299. Renew secondary air pump.
Don't miss
- Secondary air pump relay J299 is supplied with power via fuel pump relay J17.
- Connect adapter cable, 121-pinV.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth 24.
- Shown in illustration with bumper removed.
📋 Procedure
- Connect up vehicle diagnostic, testing and information system VAS 5051B with diagnosis lead VAS 5051/1, press Vehicle self-diagnosis key and select vehicle system "“01 - Engine electronics”". When doing this, the engine must be running at idling speed.
- From list (1), select diagnosis function "“02 - Interrogate fault memory”".
- Terminate function "“02 - Interrogate fault memory”" by touching ← key.
- Press function "“06 - End output”".
- Switch ignition off and then on again and select vehicle system "“01 - Engine electronics”" again if necessary.
- From the menu (1) select the diagnostic function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press the diagnostic function "“06 - end output”" and switch off the ignition.
- Check voltage supply of secondary air pump relay J299.
- Check activation of secondary air pump relay J299.
- Check voltage supply for secondary air pump motor V101. [Note: Secondary air pump relay J299 is supplied with power via fuel pump relay J17.]
- Pull off rubber seal in direction of (arrow) and remove plenum chamber cover (1) to front.
- Remove cover for electronics box in plenum chamber (arrows).
- Disconnect secondary air pump relay J299(Item 2).
- Connect hand-held multimeter V.A.G 1526C (voltage measuring range) between contact (8) of relay socket and earth "“–”".
- Repair wiring from contact (8) of relay socket, via fuse, to battery "“+”" (terminal 30) (see the separate procedure).
- Connect hand-held multimeter V.A.G 1526C (voltage measuring range) between contact (4) of relay socket and earth "“–”".
- Operate the starter briefly.
- Switch off ignition.
- Repair wiring from relay socket contact (4), via fuse, to fuel pump relay J17.
- Connect voltage tester V.A.G 1527B (voltage measuring range) between contact (6) of relay socket and earth "“–”".
- Switch on ignition and select vehicle system "“01 - Engine electronics”".
- Repeat function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press function "“06 - End output”" and switch off ignition.
- Connect adapter cable, 121-pin V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (repair group 24).
- ⚠ To prevent damage to electronic components, select appropriate measuring range before connecting measuring leads and observe test requirements. — Check for open circuit and short to positive or earth in the following wiring:
- Repair wiring connection if necessary.
- Renew secondary air pump relay J299.
- Vehicles with auxiliary heater: remove bolts (arrows) securing exhaust pipe for auxiliary/additional heater to noise insulation.
- Release fasteners (1 … 4) and take off noise insulation.
- Unplug electrical connector (1) at secondary air pump motor V101. [Note: Shown in illustration with bumper removed.]
- Connect voltage tester V.A.G 1527B between contact (1) and (2) of connector for secondary air pump motor V101.
- Switch on ignition and select vehicle system "“01 - Engine electronics”".
- Repeat function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press function "“06 - End output”".
- Switch off ignition and unplug diagnostic connector.
- Check wiring between electrical connector at secondary air pump motor V101 and secondary air pump relay J299(item 2) (in electronics box, plenum chamber).
- Check for open circuit in wiring between connector at secondary air pump motor V101 and earth (see the separate procedure).
- Renew secondary air pump.
📐 11 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking secondary air pump relay J299 and activation – Audi
- Checking secondary air pump relay J299 and actuation
- Checking secondary air pump relay J299 or J316 and activation
- Checking voltage supply of secondary air pump motor V101 and secondary air pump motor 2V189
- Checking voltage supply of secondary air pump relay J299.
- Removing and installing secondary air pump motor V101 – Audi
- Checking system pressure – Audi A8 D3
- Removing and installing front exhaust pipe (right-side) with catalytic converter - vehicles with manual gearbox
- Checking delivery rate of fuel pumps - vehicles with 6-cylinder engine
- Checking delivery rate of fuel pumps - vehicles with fuel return line
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.