Checking voltage supply of secondary air pump motor V101 and secondary air pump motor 2V189: Audi A8 D2 (4D) (AZC)
Checking voltage supply of secondary air pump motor V101 and secondary air pump motor 2V189 — Audi… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A8 D2 (4D)
- Replacement notes from the steps (read the conditions below): Renew secondary air pump motorV101; see Removing and installing secondary air pump . Renew secondary air pump motor 2V189; see Removing and installing secondary air pump .
- Also covered elsewhere: Removing and installing secondary air pump
Don't miss
- The coolant hoses remain connected.Hot steam and hot coolant can be released when the coolant system is opened.
- Shown with coolant expansion tank removed for illustration purposes.
- Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.
- The hoses on filler neck and on reservoir for power steering remain connected.
🔧 Engine codes recorded for this source
📋 Procedure
- Remove cover (right-side) in engine compartment (arrows).
- Unbolt coolant expansion tank (arrows).
- Unplug electrical connector for coolant shortage indicator switch F66 at expansion tank (below). [Note: The coolant hoses remain connected. Hot steam and hot coolant can be released when the coolant system is opened.]
- Unplug electrical connector (arrow) at secondary air pump motor V101 using tool T10118. [Note: Shown with coolant expansion tank removed for illustration purposes.]
- Connect voltage tester V.A.G 1527 B between contacts (1) and (2).
- Under selection menu (1) select the diagnostic function "“03 - Final control diagnosis”".
- Press the button → until the secondary air pump relay J299 is activated. [Note: Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.]
- Exit function "“03 - Final control diagnosis”" by pressing the ← key.
- Press the diagnostic function "“06 - end output”" and switch off the ignition.
- Use leads from adapter set V.A.G 1594 A to bridge contacts 1 and 46 at test box.
- Use current flow diagram to check for open circuit in wiring leading from contact 2 of connector going to secondary air pump relay J299 on relay carrier in electronics box (plenum chamber).
- Use current flow diagram to check for open circuit in wiring leading from contact 1 of connector to earth.
- Renew secondary air pump motor V101; see Removing and installing secondary air pump (see the separate procedure).
- Remove cover (left-side) in engine compartment (arrows).
- Unscrew securing bolts for filler neck of windscreen washer fluid reservoir (2).
- Unscrew bolts and detach reservoir (1) for power steering at bracket. [Note: The hoses on filler neck and on reservoir for power steering remain connected.]
- Lay the filler neck for windscreen washer fluid reservoir forwards.
- Unplug electrical connector (arrow) at secondary air pump motor 2V189.
- Connect voltage tester V.A.G 1527 B between contacts (1) and (2).
- Under selection menu (1) select the diagnostic function "“03 - Final control diagnosis”".
- Press the button → until the secondary air pump relay 2J545 is activated. [Note: Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.]
- Exit function "“03 - Final control diagnosis”" by pressing the ← key.
- Press the diagnostic function "“06 - end output”" and switch off the ignition.
- Use leads from adapter set V.A.G 1594 A to bridge contacts 1 and 46 at test box.
- Use current flow diagram to check for open circuit in wiring leading from contact 2 of connector going to secondary air pump relay 2J545 on relay carrier in electronics box (plenum chamber).
- Use current flow diagram to check for open circuit in wiring leading from contact 1 of connector to earth.
- Renew secondary air pump motor 2V189; see Removing and installing secondary air pump (see the separate procedure).
Other AUDI procedures
- Checking voltage supply of secondary air pump motor V101
- Checking voltage supply of secondary air pump motor V101 and secondary air pump motor 2 V189
- Checking voltage supply of secondary air pump relay J299.
- Checking secondary air pump relay J299 and secondary air pump motor V101
- Removing and installing secondary air pump motor V101 – Audi
- Removing and installing secondary air pump motor V101 (in rear wheel housing) - R8 Coupé
- Checking angle sender for throttle valve actuator
- Checking misfire detection
- Checking ignition coils
- Checking Hall senders (camshaft position sensors) – Audi 6.0
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.