📋 Procedure
Checking voltage supply of secondary air pump motor
V101 and secondary air pump motor 2
V189
Special tools and workshop equipment required
Assembly tool
T10118
- only for secondary air pump motor
V101
, cylinder bank 1 (right-side)
Secondary air pump motor
V101 for cylinder bank 1 (right-side):
Remove cover (right-side) in engine compartment (arrows).
Unbolt coolant expansion tank (arrows).
Unplug electrical connector for coolant shortage indicator switch
F66 at expansion tank (below).
Note
The coolant hoses remain connected.
Hot steam and hot coolant can be released when the coolant system is opened.
Unplug electrical connector (arrow) at secondary air pump motor
V101 using tool
T10118.
Note
Shown with coolant expansion tank removed for illustration purposes.
Connect voltage tester
V.A.G 1527 B between contacts (1) and (2).
Vehicle diagnostic, testing and information system
VAS 5051 with diagnosis lead
VAS 5051/1 is connected; vehicle self-diagnosis and vehicle system
“01 - Engine electronics” is selected. When doing this the ignition must be switched on.
Under selection menu (1) select the diagnostic function
“03 - Final control diagnosis”.
Press the button
→ until the secondary air pump relay
J299 is activated.
LED should flash slowly.
Note
Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.
Exit function
“03 - Final control diagnosis” by pressing the
← key.
Press the diagnostic function
“06 - end output” and switch off the ignition.
If the LED does not flash:
Use leads from adapter set
V.A.G 1594 A to bridge contacts 1 and 46 at test box.
The LED should light up.
If the LED does not light up:
Use current flow diagram to check for open circuit in wiring leading from contact 2 of connector going to secondary air pump relay
J299 on relay carrier in electronics box (plenum chamber).
Use current flow diagram to check for open circuit in wiring leading from contact 1 of connector to earth.
If no fault is found:
Renew secondary air pump motor
V101
; see Removing and installing secondary air pump (see the separate procedure).
Secondary air pump motor 2
V189 for cylinder bank 2 (left-side):
Remove cover (left-side) in engine compartment (arrows).
Unscrew securing bolts for filler neck of windscreen washer fluid reservoir (2).
Unscrew bolts and detach reservoir (1) for power steering at bracket.
Note
The hoses on filler neck and on reservoir for power steering remain connected.
Lay the filler neck for windscreen washer fluid reservoir forwards.
Unplug electrical connector (arrow) at secondary air pump motor 2
V189.
Connect voltage tester
V.A.G 1527 B between contacts (1) and (2).
Vehicle diagnostic, testing and information system
VAS 5051 with diagnosis lead
VAS 5051/1 is connected; vehicle self-diagnosis and vehicle system
“11 - Engine electronics II” is selected. When doing this the ignition must be switched on.
Under selection menu (1) select the diagnostic function
“03 - Final control diagnosis”.
Press the button
→ until the secondary air pump relay 2
J545 is activated.
LED should flash slowly.
Note
Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.
Exit function
“03 - Final control diagnosis” by pressing the
← key.
Press the diagnostic function
“06 - end output” and switch off the ignition.
If the LED does not flash:
Use leads from adapter set
V.A.G 1594 A to bridge contacts 1 and 46 at test box.
The LED should light up.
If the LED does not light up:
Use current flow diagram to check for open circuit in wiring leading from contact 2 of connector going to secondary air pump relay 2
J545 on relay carrier in electronics box (plenum chamber).
Use current flow diagram to check for open circuit in wiring leading from contact 1 of connector to earth.
If no fault is found:
Renew secondary air pump motor 2
V189
; see Removing and installing secondary air pump (see the separate procedure).
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking voltage supply of secondary air pump motor V101
- Checking voltage supply of secondary air pump motor V101 and secondary air pump motor 2V189
- Checking voltage supply of secondary air pump relay J299.
- Checking secondary air pump relay J299 and secondary air pump motor V101
- Removing and installing secondary air pump motor V101 / V189
- Checking activation of secondary air pump relay – Audi A4 B5
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.