Checking secondary air pump relay J299 and activation: Audi A4 B5 (8D) (ASJ, AZR)
Checking secondary air pump relay J299 and activation — Audi A4 B5 (8D) (ASJ, AZR). Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A4 B5 (8D)
- Replacement notes from the steps (read the conditions below): Renew secondary air pump relayJ299. Renew secondary air pump.
Don't miss
- Connect adapter cableV.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (not shown in illustration).
- Disregard items marked (1) and (3).
📋 Procedure
- Open rear ashtray and remove cover for diagnostic connector.
- Connect up vehicle diagnostic, testing and information system VAS 5051 with diagnosis lead VAS 5051/1, press vehicle self-diagnosis button and select vehicle system "“01 - Engine electronics”". When doing this, the engine must be running at idling speed.
- From list (1), select diagnosis function "“02 - Interrogate fault memory”".
- Terminate function "“02 - Interrogate fault memory”" by touching ← key.
- From the menu (1) select the diagnostic function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press the diagnostic function "“06 - end output”" and switch off the ignition.
- Check voltage supply of secondary air pump relay J299.
- Check activation of secondary air pump relay J299.
- Check voltage supply for secondary air pump motor V101.
- Run windscreen wipers to the vertical position.
- Detach rubber seal from plenum chamber cover in direction of (arrow).
- Detach plenum chamber cover (1) towards the front.
- Remove cover for electronics box in plenum chamber (arrows).
- Disconnect secondary air pump relay J299(Item 2).
- Connect hand-held multimeter V.A.G 1526 C (voltage measuring range) between relay socket, contact (8) and earth.
- Check secondary air pump fuse S130(item 4).
- Check for open circuit in wiring from battery "“+”" (terminal 30), via secondary air pump fuse S130(item 4) to secondary air pump relay J299(item 2).
- Connect hand-held multimeter V.A.G 1526 C (voltage measuring range) between relay socket, contact (4) and earth.
- Operate the starter briefly.
- Repair wiring harness according to current flow diagram.
- Switch off ignition.
- Disconnect secondary air pump relay J299.
- Connect up voltage tester V.A.G 1527 B between relay socket contact (6) and battery positive.
- Switch on ignition and select vehicle system "“01 - Engine electronics”".
- Repeat function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press function "“06 - End output”" and switch off ignition.
- Connect adapter cable V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (not shown in illustration).
- ⚠ To prevent damage to electronic components, select appropriate measuring range before connecting measuring leads and observe test requirements. — Check for open circuit and short to positive or earth in the following wiring:
- Repair wiring connection if necessary.
- Renew secondary air pump relay J299.
- Unplug electrical connector (2) at secondary air pump motor V101. [Note: Disregard items marked (1) and (3).]
- Connect voltage tester V.A.G 1527 B between contact (1) and (2) of connector for secondary air pump motor V101.
- Switch on ignition and select vehicle system "“01 - Engine electronics”".
- Repeat function "“03 - Final control diagnosis”".
- Press the → key repeatedly until the following display appears:
- Press the ← key to exit from function "“03 - Final control diagnosis”".
- Press function "“06 - End output”".
- Switch off ignition and unplug diagnostic connector.
- Use current flow diagram to check for open circuit in wiring between connector at secondary air pump motor V101 and secondary air pump relay J299(item 2) (in electronics box in plenum chamber).
- Use current flow diagram to check for open circuit in wiring between connector at secondary air pump motor V101 and earth.
- Renew secondary air pump.
Other AUDI procedures
- Checking secondary air pump relay J299 or J316 and activation
- Checking activation of secondary air pump relay – Audi A4 B5
- Checking secondary air pump relay J299 and activation
- Checking secondary air pump relay J299 or J316 and activation
- Checking secondary air pump relay J299 and actuation
- Checking secondary air pump relay J299 and secondary air pump motor V101
- Checking ignition coils
- Removing and installing fuel delivery unit - vehicles with 6-cylinder turbo engine
- Removing and installing exhaust gas temperature sender 1 for cylinder bank 2 G236
- Testing fuel pump relay and activation
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.