Checking air recirculation flap control motor V113: automatically controlled air conditioner — Audi A1 (8X)

Checking air recirculation flap control motor V113 — automatically controlled air conditioner… Read available instructions and vehicle application notes.

13 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A1 (8X, 2010–2018)

Don't miss

  • Operation of control motor is displayed in "“Read measured values”" function , "“Guided Fault Finding”".

📋 Procedure

  1. Remove glove box General body repairs, interior 68. Shelves / trim panels; Removing and installing glove box.
  2. Switch on ignition. [Note: Operation of control motor is displayed in "“Read measured values”" function , "“Guided Fault Finding”".]
  1. Set the rotary fresh air blower switch (3) to speed "“3”".
  2. Set the rotary air distribution switch (5) to "“Dash panel vents”".
  3. Fresh air/air recirculation button (4) not pressed.
  1. Press the fresh air/air recirculation button.
  1. Press the "“Defrost”" button (2). [Note: If operation is not OK, check electronics in Climatronic control unit J255 and activation of air recirculation flap control motor V113, "“Guided Fault Finding”".At present, the "“air recirculation mode”" function is cancelled automatically after switching the ignition on again.]
  1. Dust and pollen filter for contamination
  2. Forced ventilation vents for passenger compartment
  3. Ingress of water into passenger compartment
  4. Fresh-air intake from plenum chamber and plenum chamber water drain
  5. Seals between individual components of fresh air intake and vehicle for damage and leaks
  6. Activation of air conditioner compressor regulating valve N280 and operation of air conditioner Checking cooling output [Note: Under certain operating conditions, residual moisture in the refrigerant circuit may lead to the formation of ice at N280 (and at the expansion valve). Such ice formation impedes the control of the air conditioner compressor. The evaporator is cooled down too much and ices up. Icing-up of the evaporator may be the cause of the windows misting up.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.