The work sequence is dependent upon the programme level of the Digifant control unit. Programme level number => Page
01-3
, connecting fault reader V.A.G 1551 and selecting engine electronics control unit.
Coolant temperature above 80 °C
Connect fault reader V.A.G 1551 and select engine electronics control unit (address word 01); selection is carried out with engine idling.
=> Page
01-3
Rapid data transfer
HELP
Select function XX
Indicated on display:
Input 08 for "Read measured value block" function and confirm with Q.
Read measured value block
HELP
Input display group number XX
Indicated on display:
037906024D
DIGIFANT
1.7
1083
Coding
Up to programme level number 1083
(From programme level number 1390 =>Page
24-50)
Input 02 for display group 02 and confirm with Q.
Read measured value block 2
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)
Note:
If something different is indicated on the display:
=> Fault reader operating instructions
Read off displayed figure in display zone 4.
Specification: 10...30 % when idling the figure must increase when revving-up
Press ⇒ key.
Input 06 for "End output" and confirm with Q.
If the specification is not attained or is exceeded:
Check idling speed stabilization => Page
01-13
, Final control diagnosis
Check air intake system for leaks
=> Page
24-66.
If no fault is found:
Renew air mass meter => Page
24-8
, item (7) and perform idling check.
037906024D
DIGIFANT
1.7
1390
Coding
From programme level number 1390
Input 03 for display group 03 and confirm with Q.
Read measured value block 3
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)
Note:
If something different is indicated on the display:
=> Fault reader operating instructions
Read off displayed figure in display zone 4.
Specification: 10...30 % at idle
Press ⇒ key.
Input 06 for "End output" and confirm with Q.
If the specification is not attained or is exceeded:
Check idling speed stabilization => Page
01-13
, Final control diagnosis
Check air intake system for leaks
=> Page
24-66.
If no fault is found:
Renew air mass meter => Page
24-8
, item (7) and perform idling check.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other VW procedures
- Checking air mass meter – VW Passat B5 2.3 AZX
- Checking air mass meter G70
- Checking exhaust gas recirculation and air mass meter function
- Checking exhaust gas recirculation and air mass meter function via final control diagnosis
- Removing and installing air mass meter – VW Jetta VI
- Removing and installing air mass meter G70
- Removing engine
- Removing and installing camshaft – VW Golf Cabriolet
- Adjusting valve timing – VW Passat B5
- Removing and installing camshafts – VW Passat B6
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.