TorqFix

Testing lambda probe heating -Z29 at lambda probe (after catalytic converter): Audi

Testing lambda probe heating -Z29 at lambda probe (after catalytic converter) — Audi. Original source text. Check the document conditions against your vehicle.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

ARG AVV
Special tools and workshop equipment required

V.A.G 1526 A
V.A.G 1594 A
V.A.G 1598/31

Requirements for test:

Coolant temperature at least 80 °C

Fuse for lambda probe heating OK

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test sequence

Unplug 4-pin connector (brown) for lambda probe (after catalytic converter) -G130.

Note:

For access to connector, unscrew bolts securing coolant expansion tank and pivot expansion tank clear to the side. The coolant hoses do not have to be disconnected.

Connect multimeter (resistance measurement range) between contacts 1 and 2.
Specification: 2 ... 15ω(at room temperature)

If the specification is not attained:

Replace the lambda probe (after catalytic converter) -G130.

If the specification is obtained:

Test voltage supply for lambda probe heating.

Testing voltage supply for lambda probe heating

Connect multimeter (voltage measurement range) between contacts 1 (positive) and 2 (earth).
Start the engine.
Specification: approx. battery voltage

Note:

If required, observe Display Group 041, display zone 4 in the "Read measured value block" function to find out when the engine control unit is switching the lambda probe heating on and off.

If no voltage is present:

Connect multimeter (voltage measurement range) as follows:

Connector / Contact · Measure against
1 (positive) · Vehicle earth

Operate starter briefly.
Specification: approx. battery voltage

If there is still no voltage reading:

Test for open circuit in wiring connection between fuel pump relay and contact 1 on connector via fuse:

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

If the voltage supply is OK:

Connect multimeter (voltage measurement range) as follows:

Connector / Contact · Measure against
2 (switched earth / connection from engine control unit) · Battery positive

Start the engine.
Specification: approx. battery voltage (may fluctuate)

Switch off ignition.

If no voltage is present:

Connect test box V.A.G 1598/31 to wiring harness for engine control unit. Do not connect to the engine control unit itself.
=> Page
24-10.

Test for open circuits in the following wiring connection:

Connector / Contact · Test box V.A.G 1598/31 / Socket
2 · 63

Rectify any open circuits.

If the wiring connection is O.K. but the lambda probe heating still has no earth connection:

Fit a new engine control unit => Page
24-13.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.