TorqFix

Checking Lambda probe 1 heater after catalytic converter Z29 for Lambda probe after catalytic converter G130: Audi

Checking Lambda probe 1 heater after catalytic converter Z29 for Lambda probe after catalytic… Read available instructions and vehicle application notes.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Checking
Lambda probe 1 heater after catalytic converter
Z29 for
Lambda probe after catalytic converter
G130
Special tools and workshop equipment required
V.A.G 1526 A
V.A.G 1594 A
V.A.G 1598/31
Test sequence
Note
Coolant temperature at least 80 °C
Fuse for Lambda probe heating OK
Current flow diagrams, Electrical fault finding and Fitting locations
Unscrew the protective cover (arrows).
Unplug the 4-pin connector (brown) to the
Lambda probe after catalytic converter
G130.
Connect up the multimeter (resistance measuring range) between contacts 1 and 2.
Specification: 6.4 ... 47.5 Ω (at room temperature)
If the reading does not match the specification:
Replace the
Lambda probe after catalytic converter
G130.
If the reading matches the specification:
Check voltage supply for Lambda probe heating.
Checking voltage supply of
Lambda probe 1 heater after catalytic converter
Z29
Connect up the multimeter (voltage measuring range) between contacts 1 (positive) and 2 (earth).
Start engine.
Specification: approx. battery voltage
Note
The point at which the engine control unit switches the Lambda probe heating on and off can be observed if applicable in the
“Reading measured value block” function, display group number 041, display zone 4.
If there is no voltage:
Connect up the multimeter (voltage measuring range) as follows:
Connector
Contact
Measure to
1 (positive)
Vehicle earth
Briefly operate the starter.
Specification: approx. battery voltage
If there is still no voltage:
Check for open circuit in the wiring from contact 1 of the connector via the fuse to the fuel pump relay:
If the voltage supply is OK:
Connect up the multimeter (voltage measuring range) as follows:
Connector
Contact
Measure to
2 (engine control unit switched earth connection)
Battery positive
Start engine.
Specification: approx. battery voltage (may fluctuate)
Switch off ignition.
If there is no voltage:
Connect the test box
V.A.G 1598/31 to the wiring harness to the engine control unit, but do not connect the actual engine control unit (see the separate procedure).
Check for open circuit in the following wiring:
Connector
Contact
Test box
V.A.G 1598/31
Socket (2) (63)
Eliminate open circuit in wiring if necessary.
If the wiring is OK but there is no earth supply for the Lambda probe heating:
Replace the engine control unit (see the separate procedure).

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.