Renewing needle bearings (polygon bearings) and seal for needle bearing on flange shaft (right-side): Audi A3 (8P) / TT Mk2 (8J)
Renewing needle bearings (polygon bearings) and seal for needle bearing on flange shaft… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8P, 2003–2012), Audi TT Mk2 (8J, 2006–2014)
- Opens: gearbox oil
- Special tools named: VAS 6208, puller
Don't miss
- (Arrows) can be disregarded.
- The stepped shoulders (arrows) must then be below needle bearing.
📋 Procedure
- Position drip tray, e.g. VAS 6208 below.
- Using socket and extended bit T10107 A, remove bolt securing flange shaft (right-side). To do so, screw two bolts into flange and counterhold flange shaft with a tyre iron or other suitable lever. [Note: (Arrows) can be disregarded.]
- Attach puller T10037 to flange shaft (right-side).
- Use knurled nut T10037/1 and spindle to align puller(A) parallel with flange.
- Pull out flange shaft (right-side).
- Align both parts of clamp so that marks "“B”" are facing together.
- The stepped shoulders (arrows) must then be below needle bearing.
- Screw both halves together as far as stop.
- Remove circlip (A) for needle bearings.
- To prevent contact surface for needle bearings on flange shaft from being damaged, rotate flange shaft when pressing off (arrow).
- Remove seal (A) from groove (arrow).
- Lightly lubricate seal (A) with gear oil.
- Fit seal (A) in groove (arrow) on flange shaft.
- Attach clamp T10047 to flange shaft ⇒ illustration N39-10212 .
- To prevent contact surface of needle bearings on flange shaft from being damaged, rotate flange shaft when pressing off (arrow).
- Secure needle bearings on flange shaft with a new circlip.
- Carefully drive in flange shaft (while turning).
- Secure flange shaft with countersunk bolt; tightening torque (see the separate procedure).
- Check gear oil level in bevel box 6-speed manual gearbox34.
- Check gear oil level in bevel box 6-speed manual gearbox 39. Gear oil; Checking gear oil level.
Other AUDI procedures
- Renewing needle bearing (polygon bearing) for right flange shaft, and seal on right flange shaft
- Renewing needle bearing (polygon bearing) on stub shaft of bevel box
- Renewing needle bearing (polygon bearing) on stub shaft of bevel box (bevel box removed)
- Renewing needle bearings and flange shaft oil seal (right-side)
- Renewing needle bearings (polygon bearings) for flange shaft (right-side)
- Renewing needle bearings (polygon bearings) for flange shaft (right-side) - vehicles with 4-cylinder engine
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.