Renewing and adjusting vacuum unit for turbocharger: vehicles with engine code BLS from model year 2008 onwards only — Audi A3 (8P)
Renewing and adjusting vacuum unit for turbocharger — vehicles with engine code BLS from model… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8P, 2003–2012)
- Special tools named: feeler gauge
- Replacement notes from the steps (read the conditions below): ⚠ Only use new bolts and nuts from replacement part kit. — If necessary, remove bottom nut securing control rod from new vacuum unit (from replacement part kit).
Don't miss
- It is important that you counterhold connection when loosening oil supply line. Risk of further damage occurring later. — Counterhold connection and remove oil supply line (arrow) from turbocharger.
- Counterhold lock nut (B) with ring spanner T10423 and remove securing nut (A) from control rod using socket T10454.
- The marking can be used to determine whether the control rod has turned out of position during tightening; the position can then be corrected.
- When setting value 2, an accuracy of +/– 20 mbar is sufficient.Please ensure that adjusting lever on turbocharger can be moved easily on control rod.
- During next work step, make sure that adjusting lever (1) makes contact with adjuster screw (2) and does not rest on securing nut (A).If this is the case, screw securing nut (A) back.
🔩 Torque settings
Values can differ between engine variants — check the code stamped on your block.
| Torque | Fastener / step |
|---|---|
| 8 Nm (5.9 lb-ft) | Tighten bolts (1) and (2) to 8 Nm. |
ℹ️ Always cross-check the exact figure against your vehicle's factory manual before final tightening — a wrong torque can damage the engine. These values are extracted from workshop data and may not cover every variant or revision.
📋 Procedure
- ⚠ The tools listed, in particular the socket T10454, are only intended for use according to the procedure described in the following; do NOT use the tools for other bolted connections. There is danger of deformation if the specified torques are exceeded. — Remove engine cover panel.
- Release clips on sides (arrows) and pull cover off air duct.
- Release clips on left and right (arrow A) and unclip air duct at bottom (2).
- Swivel air duct (bottom) slightly to the rear and detach air duct (bottom) from retainers (3).
- Detach air pipe (1) from air duct (bottom) (arrow B).
- Unplug electrical connector (1) from air mass meter G70.
- Detach vent hose (3) and air hose (2).
- Unscrew bolt (4) and detach air cleaner housing.
- Detach crankcase breather hose (2).
- Move vent hose (4) and vacuum hoses (1) clear at air hose.
- Remove bolt (3).
- Swing air hose to rear and detach from turbocharger.
- Seal opening in turbocharger with plug from replacement part kit.
- Disconnect vacuum hose from turbocharger.
- Depending on version, remove nut (arrow) securing oil supply line/vacuum line to cylinder head.
- ⚠ It is important that you counterhold connection when loosening oil supply line. Risk of further damage occurring later. — Counterhold connection and remove oil supply line (arrow) from turbocharger.
- Seal opening for oil supply line in turbocharger with plug from replacement part kit.
- Counterhold lock nut (B) with ring spanner T10423 and remove securing nut (A) from control rod using socket T10454.
- Remove securing bolts (1) and then (2) and detach vacuum unit (A).
- Mark vacuum unit and control rod as shown. [Note: The marking can be used to determine whether the control rod has turned out of position during tightening; the position can then be corrected.]
- ⚠ Only use new bolts and nuts from replacement part kit. — If necessary, remove bottom nut securing control rod from new vacuum unit (from replacement part kit).
- Screw lock nut onto control rod by hand towards vacuum unit as far as stop.
- Guide control rod through adjusting lever on turbocharger, fit vacuum unit (A) and screw in bolts until they make contact.
- Fit bolts (1) and(2) from replacement part kit.
- Tighten bolts (1) and (2) to 8 Nm. — 8 Nm (5.9 lb-ft)
- Switch on turbocharger tester V.A.G 1397A and set sliding switch to position "“I”".
- Subtract 600 mbar from atmospheric pressure displayed and make note of value (value 1).
- Subtract 650 mbar from atmospheric pressure displayed and make note of value (value 2).
- Set up measuring equipment and testers as shown in illustration and connect to connection "“I”"(arrow) of turbocharger tester V.A.G 1397A and to vacuum unit for turbocharger.
- Close lever (1) on pressure control valve VAS 6342.
- Move adjuster ring (1) on hand vacuum pump VAS 6213 to position (A) to select "“vacuum”". [Note: When setting value 2, an accuracy of +/– 20 mbar is sufficient. Please ensure that adjusting lever on turbocharger can be moved easily on control rod.]
- ⚠ Risk of damage to vacuum unit on account of excessive pressure. Pressure must not be below atmospheric pressure displayed minus 800 mbar. — Operate hand vacuum pump VAS 6213 several times until pressure displayed on turbocharger tester V.A.G 1397A equals value 2 noted down previously.
- Set value 1 noted previously exactly by opening pressure control valve(1).
- Screw securing nut (A) several turns onto control rod. [Note: During next work step, make sure that adjusting lever (1) makes contact with adjuster screw (2) and does not rest on securing nut (A).If this is the case, screw securing nut (A) back.]
- Hold adjusting lever (1) so that it makes contact with adjusting nut (2).
- Slowly screw lock nut (B) for control rod downwards by hand until it makes contact with adjusting lever (1); do not screw any further.
- Screw securing nut (A) on control rod against adjusting lever. [Note: When tightening securing nut (A), make sure that control rod does not turn out of position.]
- Counterhold lock nut (B) with ring spanner T10423 and tighten securing nut (A) using socket T10454.
- Checked markings on control rod; markings must be in line as shown.
- Relieve pressure; to do so move adjuster ring (1) on hand vacuum pump to position (B) and then back to position (A). [Note: There is little room between the cylinder head and the turbocharger. Make sure that you are positioning the feeler gauge (0.05 mm) correctly.]
- Position feeler gauge (0.05 mm) between adjusting lever and adjuster screw. [Note: The feeler gauge (0.05 mm) has a part number and must be ordered via the Electronic parts catalogue.]
- Now operate hand vacuum pump VAS 6213 until feeler gauge (0.05 mm) is clamped between adjusting lever and adjuster screw.
- Seal connection between control rod and securing nut with sealing paint from replacement part kit.
- Press locking plate onto control rod by hand and turn by 90° in direction of (arrow).
- Counterhold connection and tighten oil supply line (arrow) on turbocharger.
- Depending on version, fit nut (arrow) securing oil supply line/vacuum line to cylinder head and tighten connection.
- Fully assemble engine components.
- Start engine and erase event memory (see the separate procedure).
Other AUDI procedures
- Changing and adjusting vacuum unit on turbocharger, only vehicles with engine codes BLS and BSU as of model year 2008
- Adjusting vacuum unit for turbocharger, engines with code letters AXX, BPY, BWA
- Renewing vacuum unit for turbocharger – Audi TT Mk2
- Adjusting vacuum unit for low-pressure turbocharger – Audi
- Adjusting vacuum unit for low-pressure turbocharger - vehicles with engine codes CGQB, CVUB, CVUC, DEHA
- Adjusting vacuum unit for turbocharger – Audi A1
- Removing and installing tandem pump - vehicles with 2-valve engine
- Measuring axial clearance of camshaft – Audi A6/A7 C7
- Draining and filling coolant
- Emptying fuel tank if it is less than 3/4 full
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.