TorqFix

Removing and installing rear left vent warm air and cold air flap control motor V220: Audi A8 D3 (4E)

Removing and installing rear left vent warm air and cold air flap control motor V220 — Audi A8 D3… Read available instructions and vehicle application notes.

10 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A8 D3 (4E, 2002–2010)

  • Special tools named: VAS 5051

📋 Procedure

  1. Switch off ignition.
  2. Remove the centre console. 70
  3. Remove the air duct from the centre console 68
  4. Remove the bolts (A).
  5. Detach the control motor (B).
  6. Use 2 screwdrivers (C) to prise off the connecting element (D).
  1. Attach the connecting element (A) to the control motor shaft. [Note: Check the positioning of the connecting element. It must engage in the mount of the motor and there must not be any clearance between the control motor mount and the connecting element. Pay attention to correct assignment of the connecting element ("„red“" colour for left control motor and "„blue“" colour for right control motor).The connecting piece is only to be attached in the position in which it engages without having to exert force. If pre-tension is required to insert the connecting piece, check the mount of the motor as this may be turned through 180°.The control motor shaft (B) has no stop. It rotates constantly if voltage is applied between contacts 5 and 6. When the control motor has been detached, voltage is therefore only to be applied with the connecting element -A- attached. The motor may be incorrectly positioned if pre-tension is required to insert the connecting piece (A) in the control motor. If the shaft is so awkwardly positioned that the connecting piece cannot be attached, use an adapter cable for example or a test lead from the adapter set V.A.G 1594/C to connect contacts 5 and 6 of the control motor by way of a 5 A fuse to a 12 V battery. In the event of the fault "„Upper or lower limit value exceeded“", check the motor/flap connecting element. It must be properly attached to the motor and there must not be any clearance between the control motor mount and the connecting element. Turn the control motor until no pre-tension is required to attach the intermediate piece. The direction of rotation can be reversed by interchanging positive and negative.]
  1. Re-install the components removed in reverse order.
  2. Interrogate the fault memory of the front operating and display unit, Climatronic control unit J255 and erase any faults displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  3. Perform basic setting and final control diagnosis for the air conditioner. "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.