📋 Procedure

Checking
Climatronic control unit
J255 and air recirculation flap control motor
V113
Note
Depending on the operating unit (
Climatronic control unit
J255
), the air recirculation flap control motor
V113 on vehicles manufactured in 2010 may also be displayed as the fresh air/air recirculation, air flow flap control motor
V425 or fresh air and air recirculation flap control motor
V154
Vehicle diagnostic tester,
“Guided Fault Finding”.
Special tools and workshop equipment required
Vehicle diagnostic tester
Voltage tester
V.A.G 1527 B
Procedure
Remove glove box (repair group 68: Shelves / trim panels; Removing and installing glove box).
Switch on ignition.
Check operation of control motor via
“Read measured values” function
Vehicle diagnostic tester,
“Guided Fault Finding”.
Set the rotary air distribution switch (5) to
“Dash panel vents”.
Fresh air/air recirculation button (4) not pressed.
Fresh air mode - lamp in button is off.
Air recirculation flap control motor
V113 set to
“fresh air mode”
- fresh air flap (1) in
“open” position.
Air recirculation flap closed.
Note
This illustration shows the fresh air flap (1) with the plenum chamber cover removed.
Use voltage tester
V.A.G 1527 B and test leads from auxiliary measuring set
V.A.G 1594C at control motor (A) to connect contacts
“5” and
“6” at electrical connector (B).
Note
Leave electrical connector plugged in.
Operation of control motor is displayed in
“Read measured values” function
Vehicle diagnostic tester,
“Guided Fault Finding”.
This illustration shows the connector on a manually controlled air conditioner control motor. Use is made of additional contacts in the connector on vehicles with an automatically controlled air conditioner
Current flow diagrams, Electrical fault finding and Fitting locations.
The control motor connections are interchanged on right-hand drive vehicles
Current flow diagrams, Electrical fault finding and Fitting locations.
Press fresh air/air recirculation button (4).
The lamp in the button lights up.
“Earth” is briefly applied to contact
“5” and
“positive” is briefly applied to contact
“6”.
The air recirculation flap control motor
V113 and thus the air recirculation flap (1) move to the
“air recirculation mode” position.
The air recirculation mode opening is opened.
Note
Positive is only applied for a certain time after the fresh-air/air recirculation button has been pressed. After this period, the control motor is then only activated with a specific duty cycle (lamp in voltage tester
V.A.G 1527B only flashes briefly).
Press fresh air/air recirculation button (4).
The lamp in the button goes out.
Note
On pressing the fresh air/air recirculation button, the control unit alters the power supply to the control motor (positive and earth are interchanged).
“Earth” is briefly applied to contact
“6” and
“positive” is briefly applied to contact
“5”.
The air recirculation flap control motor
V113 and thus the air recirculation flap (1) move to the
“fresh-air mode” position.
The air recirculation mode opening is closed.
Note
The control motor connections are interchanged on right-hand drive vehicles
Current flow diagrams, Electrical fault finding and Fitting locations.
If this test does not reveal any problems with activation of air recirculation flap control motor
V113 and flap does not move properly:
Check freedom of movement of fresh air flap/air recirculation flap.
Renew
V113 (see the separate procedure).
If activation and thus operation of air recirculation flap control motor
V113 are not OK:
Check electronics in
Climatronic control unit
J255 and activation of air recirculation flap control motor
V113
Vehicle diagnostic tester,
“Guided Fault Finding”.
Check the wiring between the
Climatronic control unit
J255 and
V113 for open circuit or short circuit
Current flow diagrams, Electrical fault finding and Fitting locations.
Check the power supply and earth connection to
J255.
Renew
Climatronic control unit
J255 (see the separate procedure).
If operation of fresh air/air recirculation flap is OK and windows mist up, check the following:
Dust and pollen filter for contamination (see the separate procedure)
Forced ventilation vents for passenger compartment (see the separate procedure)
Ingress of water into passenger compartment (see the separate procedure)
Fresh-air intake from plenum chamber and plenum chamber water drain (see the separate procedure)
Seals between individual components of fresh air intake and vehicle for damage and leaks
Activation of air conditioner compressor regulating valve
N280 and operation of air conditioner (see “Checking cooling output”)

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.