TorqFix

Removing and installing plenum chamber partition panel: Audi A6/A7 C7

Step-by-step removing and installing plenum chamber partition panel for the Audi A6/A7 C7: 18 steps. What to remove, in what order, and what to check.

Workshop procedure for AUDI — the exact step sequence and torque figures, straight from real workshop data.

18 steps

🧭 Before you start

Fits: Audi A6/A7 C7 (4G, 2011–2018); platform code 4X

  • Opens: coolant
  • Special tools named: 3094

Don't miss

  • The illustration shows a vehicle with auxiliary heater.
  • Different securing methods may have been used: cable tie clip, clip or bolt.
  • Make sure that seal (2) for plenum chamber partition panel (1) is seated correctly in mounting (3) of plenum chamber.

📋 Procedure

  1. Remove body brace Running gear, axles, steering40Suspension strut, upper links; Removing and installing body brace.
  2. Release retainer (arrow A) and open cover (arrow B).
  3. Unscrew nut (3) and move clear electrical wiring.
  4. Take electrical connector (1) out of bracket.
  5. Unscrew nuts (arrows) and detach terminal 30 wiring junction 2TV22 from plenum chamber partition panel. [Note: Ignore (item 2).]
AUDI? Steps differ between engine variants — check this job against your exact car before you commit to it. Check my car — free →
  1. Move clear electrical wiring harness at plenum chamber partition panel.
  2. Cover area underneath cut-off valve with absorbent cloth or absorbent paper.
  3. Clamp off coolant hoses (1 and 3) with hose clamps 3094.
  4. Unfasten hose clips and disconnect coolant hose (2) from shut-off valve.
  5. Press grommet (4) out of plenum chamber partition panel towards engine. [Note: The illustration shows a vehicle with auxiliary heater.]
  6. If fitted, detach heat shield (1) upwards (arrow).
  7. Release fasteners (arrows A) and detach leadthrough (1) upwards (arrow B).
  8. Remove bolt (arrow). [Note: Different securing methods may have been used: cable tie clip, clip or bolt.]
  9. Disconnect vacuum line (3) for brake servo.
  10. Pull off grommet (1) for vacuum connection.
  11. Unscrew nut (2) and lift off plenum chamber partition panel (4).
  12. Make sure that seal (2) for plenum chamber partition panel (1) is seated correctly in mounting (3) of plenum chamber.
  13. Check coolant level 19Cooling system/coolant; Draining and filling cooling system.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

The figures on this page come from manufacturer workshop documentation and are shown as they are. The page is assembled automatically from that data — it is not written by an AI. The AI works in the chat, where it answers for your specific car. It writes nothing here.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix →

Workshop data on this page last updated 20 Sep 2026.