TorqFix

Removing and installing Lambda probes G39 / G108 / G130 / G131: Audi Q7 (4L)

Removing and installing Lambda probes G39 / G108 / G130 / G131 — Audi Q7 (4L). 9 source steps. Check the document conditions against your vehicle.

9 steps 8 engine codes Showing one source document; this title group contains 2 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi Q7 (4L, 2005–2015)

  • Special tools named: 3337
  • Also covered elsewhere: Electronic parts catalogue for high-temperature paste

Don't miss

  • For illustration purposes, in the following illustrations the installation position is shown from the rear with the engine removed.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Remove engine cover panel (rear) (see the separate procedure).
  2. Detach vacuum hose (1) from connection on air hose.
  3. Release hose clips (arrows) and remove air pipe.
  4. Detach relevant electrical connector from bracket on suspension turret (right-side), unplug connector and move it clear. [Note: For illustration purposes, in the following illustrations the installation position is shown from the rear with the engine removed.]
  1. Press coolant hose to the side.
  2. Unscrew Lambda probe G39(item 2) with ring spanner 3337/7.
  3. Unscrew Lambda probe after catalytic converter G130(item 1) with ring spanner 3337/2.
  4. Unscrew Lambda probe 2G108(item 1) with ring spanner 3337/7.
  5. Unscrew Lambda probe 2 after catalytic converter G131(item 2) with ring spanner 3337/1. [Note: New Lambda probes are coated with an assembly paste. In the case of a used Lambda probe, coat only the thread with high-temperature paste; refer to Electronic parts catalogue for high-temperature paste. The assembly paste / high-temperature paste must not make contact with the slots on the Lambda probe body. When installing, it is important to re-attach the Lambda probe wiring at the same locations to prevent it from coming into contact with the exhaust pipe. Hose connections and air pipes and hoses must be free of oil and grease before assembly. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue. To secure the air hoses at their connections, spray rust remover onto the worm thread of the used hose clips before installing.]

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your Audi CJTB — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.