🧭 Before you start

Models recorded for this source: Audi Q7 (4L, 2005–2015)

  • Also covered elsewhere: Electronic parts catalogue for high-temperature paste

Don't miss

  • If required, you can detach the electrical connector for the Lambda probe 2G108 from the bracket on the suspension turret (right-side) in order to improve accessibility.
  • Disregard items (1) and (3).
  • Disregard (item 3).
  • Do not disconnect crankcase breather vacuum hose (2) on USA models. Move air pipe clear instead (vacuum hose remains connected). — Loosen hose clip (1) and remove bolts (3).

🔧 Engine codes recorded for this source

BAR

📋 Procedure

  1. Activate jacking mode on vehicles with air suspension (repair group 43).
  2. Pull off engine cover panel (rear) (arrows).
  3. Pull off engine cover panel (front) (arrows).
  4. Unplug electrical connector (2) from air mass meter 2G246.
  5. Detach air intake hose (left-side) (1) from air duct.
  6. Release retaining clips (3) and detach top section of air cleaner (left-side).
  7. Detach hose (1) leading to secondary air pump.
  8. Unplug electrical connector (4) at air mass meter G70.
  9. Detach air intake hose (right-side) (3) from air duct.
  10. Release retaining clips (2) and detach top section of air cleaner (right-side) from bottom section of air cleaner. [Note: If required, you can detach the electrical connector for the Lambda probe 2G108 from the bracket on the suspension turret (right-side) in order to improve accessibility.]
  1. Press retaining ring (1) forwards off hose connector.
  2. Press down release ring (2)(arrows) and detach breather hose (3) from air cleaner (top section).
  1. Disconnect vacuum hose (2) leading to activated charcoal filter solenoid valve 1N80 by pressing release tab.
  2. Move vacuum hose clear. [Note: Disregard items (1) and (3).]
  1. Unplug electrical connector (2) at activated charcoal filter solenoid valve 1N80.
  2. Detach activated charcoal filter system solenoid valve 1N80(item 1) from bracket and move clear to one side. [Note: Disregard (item 3).]
  1. Disconnect vacuum hoses (2) and (4).
  1. ⚠ Do not disconnect crankcase breather vacuum hose (2) on USA models. Move air pipe clear instead (vacuum hose remains connected). — Loosen hose clip (1) and remove bolts (3).
  2. Take out air pipe to right side.
  3. Remove relevant electrical connector from bracket on suspension turret (right-side).
  1. Unplug electrical connector and move electrical wiring going to relevant Lambda probe clear.
  1. Unscrew Lambda probe 2G108(item 1).
  1. Unscrew Lambda probe G39(item 2).
  1. Unscrew bolts and detach noise insulation (rear) (2).
  1. Unscrew Lambda probe 2 after catalytic converter G131(item 2).
  1. Unbolt heat shield for front propshaft (arrows).
  2. Unscrew Lambda probe after catalytic converter G130(item 1). [Note: New Lambda probes are coated with an assembly paste. In the case of a used Lambda probe, coat only the thread with high-temperature paste; refer to Electronic parts catalogue for high-temperature paste. The assembly paste / high-temperature paste must not make contact with the slots on the Lambda probe body. When installing, it is important to re-attach the Lambda probe wiring at the same locations to prevent it from coming into contact with the exhaust pipe. Hose connections and air pipes and hoses must be free of oil and grease before assembly. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue. To secure the air hoses at their connections, spray rust remover onto the worm thread of the used hose clips before installing.]
  1. Deactivate jacking mode on vehicles with air suspension (repair group 43).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.