TorqFix

Removing and installing intake housing with air flow flap: Audi A8 D3 (4E)

Removing and installing intake housing with air flow flap — Audi A8 D3 (4E). 20 source steps. Check the document conditions against your vehicle.

20 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A8 D3 (4E, 2002–2010)

  • Special tools named: VAS 5051

Don't miss

  • The air flow flap must be open to gain access to the bolts (A).

📋 Procedure

  1. Remove the plenum chamber cover on the left and right.
  2. Remove the dust and pollen filter (see the separate procedure).
  3. Remove the body brace with the reinforcement to the scuttle panel trim. Running gear40
  4. Switch on the ignition and set the air conditioner to fresh-air mode (e.g. by way of "„Defrost“" setting on front operating and display unit, Climatronic control unit J255). [Note: The air flow flap must be open to gain access to the bolts (A).]
  1. Screw out the bolts (A).
  2. Switch off ignition.
  3. Then screw out the remaining bolts (arrows).
  4. Release the fasteners for the wiring harness (A) on the right and left at air conditioning unit.
  5. Detach the intake housing with air flow flap.
  6. If necessary for further work, release the remaining wiring harness fasteners at the air conditioning unit.
  7. Screw out the bolts (A).
  8. Detach the cover (B).
  9. Detach the temperature sensor from the intake housing (see the separate procedure).
  10. Remove the air flow flap control motor V71.
  1. Before fitting the intake housing, carefully seal the housing joints on the left and right in areas (C) and (D) with adhesive sealant (e.g. silicone adhesive sealant D 176 001 A3) Electronic parts catalogue.
  2. Seal the grommet through which the wiring harness is routed into the air conditioning unit (to the fresh air blower control unit J126) with adhesive sealant (e.g. silicone adhesive sealant D 176 001 A3 (to stop water running through the grommet or past the grommet into the air conditioning unit).
  3. On fitting the intake housing (B), insert a foam strip (3 x 3 mm, 130 mm long) (C) in the left and right tongue-and-groove joint between the bottom part of the housing (A) and the cover (D) and the intake housing (B) or seal these joints with adhesive sealant (e.g. silicone adhesive sealantD 176 001 A3) Electronic parts catalogue.
  4. Re-install the components removed in reverse order.
  5. Interrogate the fault memory of the front operating and display unit, Climatronic control unit J255 and erase any faults displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  6. Perform air conditioner basic setting and final control diagnosis "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.