TorqFix

Removing and installing air flow flap control motor V71 with potentiometer for air flow flap control motor G113: Audi A3 (8P)

Removing and installing air flow flap control motor V71 with potentiometer for air flow flap… Read available instructions and vehicle application notes.

27 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8P, 2003–2012)

  • Special tools named: VAS 5051

Don't miss

  • Mark the connector to the air recirculation flap control motor V113 (to prevent interchange with the connector to the air flow flap control motor V71).
  • Install the holder (A), taking particular care to ensure that the guide of the holder (B) is properly inserted in the mount of the intake housing (C) and that the holder is correctly engaged in both catches (D) and (E).
  • After installing the control motors, perform air conditioner basic setting and then interrogate the air conditioner event recorder "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.

📋 Procedure

  1. ⚠ Problems with air conditioner (heater) operation following installation of incorrect component versionsThe different control motor versions can only be distinguished from the outside based on their part numbersWhere possible, only remove a control motor once the new component is available for installation. Prior to installation, check carefully to ensure that the correct control motor is being installed. If possible, only dispose of the removed components once correct operation of the newly installed components has been checked. — Remove the glove compartment General body repairs, interior68.
  2. Switch on the ignition if necessary. On the operating and display unit, Climatronic control unit J255 select "“Defrost”" mode (control motor is always set to fresh-air position in this mode) and wait until the control motor has reached its "“fresh air mode”" end position.
  3. Switch off ignition.
  4. Release the catches (D) and (E) for the holder (A) at the intake housing and detach the holder (A).
  5. Remove the air recirculation flap control motor V113.
  6. Mark the connector to the air recirculation flap control motor V113 (to prevent interchange with the connector to the air flow flap control motor V71).
  7. Detach the control motor (A) from the intake housing. [Note: The connection between the gear wheels of the control motor and the air flow flap is designed such that the control motor can only be readily detached in the "“fresh air mode”" position. If the control motor is in a different position and can no longer be moved, it is not possible to simply detach the control motor, but rather it must first be forced out of the mounting points (B). Take care not to damage the gear wheel (C) when doing so.] [Note: Until 10.2013, the control motor was supplied as a spare part with the mounted gear wheel (A) in the "“fresh air mode”" position. From 10.2013, supply of a control motor without the gear wheel (A) mounted has gradually been phased in. You must therefore correctly assemble the gear wheel and control motor. Only when the gear wheel (A) contacts the stop (B), can it be fitted onto the gear wheel of the air flow flap. Control motors which have been removed in a different position or actuated following removal cannot be installed. If the gear wheel (A) of the control motor does not contact stop (B) ("“fresh air mode”"), move it to the position required for installation. The different colours of the gear wheels and connecting elements is only used on vehicles built until approx. 10.2013. On vehicles built after this time, these components can no longer be distinguished according to their colour .]
  1. Lever out the connecting element (here the gear wheel (A)) from the control motor being replaced (or select from the set of connecting elements) and install it in the new control motor being installed (see the separate procedure).
  2. If the gear wheel (A) of the control motor is not on the stop (B)"“fresh air mode”", use an adapter cable or an auxiliary lead from the adapter set V.A.G 1594 C for example to connect contacts 5 and 6 of the control motor via a 5 A fuse to a 12 V battery.
  3. The control motor then moves in one direction as far as the stop. Interchanging positive and negative reverses the direction.
  4. Actuate the control motor until the gear wheel (A) is on the "“fresh air mode”" stop (B) (see Fig.).
  5. Before fitting the control motor, check the mounting of the air flow flap in the intake housing and of the gear wheel (C) (air flow flap open, fresh air mode).
  6. Switch off ignition.
  7. Connect the air flow flap control motor V71 to the vehicle wiring harness (pay attention to correct pin assignment).
  8. Open the air recirculation flap (E).
  9. Reach into the intake opening for air recirculation mode and move the air flow flap (A) to the "“fresh air mode”" position (intake opening for air recirculation mode closed).
  10. Insert the control motor (B) in the direction opposite to the arrow in the mounts (C) and position it on the gear wheel (D).
  11. To enable the gear wheel at the control motor (A) to be attached to the gear wheel of the air flow flap, the short tooth (C) of the gear wheel at the control motor must coincide with the short tooth gap (D) of the gear wheel at the shaft of the air flow flap (B).
  12. Install the air recirculation flap control motor V113.
  13. Route the wiring harness such that it cannot come into contact with moving components (e.g. control motor lever).
  14. Install the holder (A), taking particular care to ensure that the guide of the holder (B) is properly inserted in the mount of the intake housing (C) and that the holder is correctly engaged in both catches (D) and (E).
  15. Check the control motors. They must be held in position by the holder (A). Eliminate any clearance if necessary by attaching a piece of foam to the inside of the attachment points (F) of the holder (A) (see the separate procedure). [Note: The position of the air flow flap control motor V71 and the air recirculation flap control motor V113 (and the associated flaps) can no longer be seen with the glove compartment fitted. It is therefore appropriate to check operation before fitting the glove compartment. If the two gear wheels (at the air flow flap control motor V71 and the air flow flap) have been assembled in the wrong position, the air flow flap will not reach its two end positions (may be detected as a fault via the "“Basic setting”" function) or the control motor will not run smoothly.]
  1. After installing the control motors, perform air conditioner basic setting and then interrogate the air conditioner event recorder "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  2. Switch on ignition.
  3. Actuate the air flow flap control motor V71 and the air recirculation flap control motor V113 by way of the operating and display unit, Climatronic control unit J255 until the gear wheel is on the "“air recirculation mode”" stop (this illustration shows the air flow flap (A) on the "“fresh air mode”" stop) and then check the position of the air flow flap (must be closed).
  4. Initially select the "“air recirculation mode”" function on the operating and display unit, Climatronic control unit J255.
  1. Select the "“fresh air mode”" function e.g. by way of "“defrost”" mode (the control motors are always set to the "“fresh air mode”" position in this mode). [Note: With the air recirculation flap (E) closed, the position of the air flow flap (A) can be seen by way of the air intake opening in the plenum chamber (remove plenum chamber cover).For regulation of the air flow, the fresh air intake duct is partially closed via the air flow flap (A) at higher vehicle speeds (as of approx. 80 km/h) by the operating and display unit, Climatronic control unit J255 (the position of the air recirculation flap (E) is specified by the operating and display unit, Climatronic control unit J255).To reduce the change in noise of the fresh air blower V2 caused by differences in air intake on switching from fresh-air to air recirculation mode or vice versa (switching is effected automatically for example on vehicles with air quality sensor G238 in the event of air pollution), the air flow flap control motor V71 and the air recirculation flap control motor V113 are actuated as follows:Switching from fresh air to air recirculation mode: The air recirculation flap (E) is opened first and the fresh-air intake duct then closed by way of the air flow flap (A).Switching from air recirculation to fresh air mode: The fresh-air intake duct is opened first by way of the air flow flap (A) and the air recirculation flap (E) then closed. In partial air recirculation mode, the air recirculation flap (E) is opened and the air flow flap (fresh-air flap) (A) moved to mid-position by the operating and display unit, Climatronic control unit J255 (fresh-air and air recirculation intake ducts are simultaneously opened slightly). This ensures improved cooling in certain temperature ranges and at the same time the intake of a certain proportion of fresh air.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.