  • Replacement notes from the steps (read the conditions below): Remove hydraulic impulse oil storage. [Note: Renew O-ring and bolts for hydraulic impulse oil storage.Ensure that connecter is properly engaged and secured.]

Don't miss

  • Risk of damage to gearbox.The engine must not be started when there is no ATF in the gearbox and the mechatronic unit is removed. — Shift selector lever to position "“P”".
  • Renew O-ring and bolts for hydraulic impulse oil storage.Ensure that connecter is properly engaged and secured.

📋 Procedure

  1. ⚠ Risk of damage to gearbox. The engine must not be started when there is no ATF in the gearbox and the mechatronic unit is removed. — Shift selector lever to position "“P”".
  2. Switch off ignition and remove ignition key.
  3. Remove ATF sump (see the separate procedure).
  4. Remove ATF filter (see the separate procedure).
  5. Carefully disconnect connector (arrow) from hydraulic impulse oil storage (1).
  1. ⚠ Risk of damaging gearbox control unit (mechatronic unit) through electrostatic discharge. Before handling electrical connector, the person handling it must "“electrostatically discharge”" himself/herself. To do so, briefly touch e.g. an earth connection, a radiator in the workshop or a lifting platform with the hand. Do not touch contacts of gearbox connector with the hand. — Unscrew bolts (arrows) from hydraulic impulse oil storage (1).
  2. Remove hydraulic impulse oil storage. [Note: Renew O-ring and bolts for hydraulic impulse oil storage. Ensure that connecter is properly engaged and secured.]
  1. Insert hydraulic impulse oil storage with new O-ring.
  2. Observe tightening sequence of bolts (see the separate procedure).
  3. Connect connector to hydraulic impulse oil storage.
  4. Install ATF filter (see the separate procedure).
  5. Install ATF sump (see the separate procedure).
  6. Fill ATF (see the separate procedure).

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your VW — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.