TorqFix

Detaching and attaching refrigerant lines at condenser — AUDI

Detaching and attaching refrigerant lines at condenser — Audi. 17 source steps. Check the document conditions against your vehicle.

17 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A6/A7 C7 (4G, 2011–2018)

  • Opens: refrigerant (A/C)
  • Replacement notes from the steps (read the conditions below): Renew O-rings; for correct version, refer to Electronic parts catalogue.
  • Also covered elsewhere: Electronic parts catalogue

📋 Procedure

  1. ⚠ Danger from escaping pressurised refrigerant. Frostbite on skin and other parts of the body. Extract the refrigerant and then immediately open up the refrigerant circuit. Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit. — Discharge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  2. Remove the lock carrier cover General body repairs, exterior 63. Front bumper; Removing and installing add-on components.
  1. Remove bumper cover (front) General body repairs, exterior 63. Bumper (front); Removing and installing bumper cover.
  1. Remove bolt (2) and disconnect refrigerant line (1).
  2. Seal off open lines and connections with clean plugs from engine bung set VAS 6122.
  3. Remove the bumper cover locking element General body repairs, exterior 63. Front bumper; Removing and installing add-on components.
  4. Remove bolt (1) and disconnect refrigerant line (2).
  5. Seal off open lines and connections with clean plugs from engine bung set VAS 6122.
  1. Renew O-rings; for correct version, refer to Electronic parts catalogue.
  2. If fitted, check that dowel pin (4) is not damaged and is seated correctly.
  3. Check guide ring (2) at refrigerant line connection for damage.
  4. Insert O-ring (3) in groove (arrow) in connection for refrigerant line (1). [Note: Coat O-rings with refrigerant oil before fitting .Make sure O-rings are seated correctly in groove (arrow) of corresponding refrigerant line. After attaching, check routing of refrigerant lines. They must be inserted in brackets provided and should not make contact with other components.]
  1. Insert refrigerant lines in corresponding connection at condenser.
  2. Tighten bolts.
  3. Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  4. Starting up air conditioner after charging refrigerant circuit and Air conditioner with refrigerant R134a 87. General information on air conditioner.
  5. As a final step, interrogate event memory and erase any entries displayed ("“Guided Fault Finding”").

📐 3 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 3 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.