📋 Procedure
Removing and installing refrigerant shut-off valve 4
N642
Special tools and workshop equipment required
Drip tray for workshop hoist
VAS 6208
Engine bung set
VAS 6122
Torque wrench
V.A.G 1410/
Hose clip pliers
V.A.G 1921
Pliers for spring-type clips
VAS 5024A
Vehicle diagnostic tester
Removing
Observe safety precautions when working on the high-voltage system (see “Safety precautions when working on high-voltage system”).
Observe safety precautions (see “Safety precautions when working on air conditioning systems”).
Observe safety precautions when working in the vicinity of high-voltage components (see “Safety precautions when working in the vicinity of high-voltage components”).
Comply with notes (see “Working on refrigerant circuit”).
Observe the risk rating of the high-voltage system (repair group 00: Risk category of the high-voltage system).
DANGER
Danger to life due to high voltage.
Severe or fatal injury due to electric shock.
The high-voltage system must be de-energised by a suitably qualified technician.
Now de-energise the high-voltage system (repair group 93: De-energising the high-voltage system).
Using
Vehicle diagnostic tester
, initiate basic setting, then perform function "Charge refrigerant circuit".
Note
Always perform the basic setting
“Charge refrigerant circuit” using the
Vehicle diagnostic tester
, to make sure that all valves of the refrigerant circuit are opened. This is the only way to extract the complete refrigerant from the circuit.
The
Vehicle diagnostic tester must not be disconnected from the vehicle during the entire extraction, evacuation and charging process.
To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
Extract refrigerant with air conditioning service station
. Comply with notes (see the separate procedure).
Remove valve unit of heat pump (see the separate procedure).
Before dismantling the valve unit, mark connectors and refrigerant lines accordingly.
Remove bolts (1).
Remove bolt (2).
Disconnect connector on refrigerant pressure and temperature sender 2
G826 (3).
Remove bolts (2).
Remove refrigerant line (1).
Disconnect connector on refrigerant shut-off valve 1
N696 (1).
Remove
refrigerant shut-off valve 1
N696.
Remove bolts (2) and (3).
Remove refrigerant line (1).
Remove bolts (2) and (3).
Remove refrigerant line (1).
Remove bolts (1).
Remove heat exchanger for heating condenser (2)
Remove bolts (2).
Remove refrigerant line (1).
Remove bolts (2).
Disconnect connector on refrigerant expansion valve 3
N638.
Remove
refrigerant expansion valve 3
N638 (1).
Remove bolt (2).
Remove refrigerant line (1).
Remove bolt (1).
Disconnect connector on refrigerant shut-off valve 4
N642 (2).
Remove
refrigerant shut-off valve 4
N642 (2).
Installing
Installation is carried out in the reverse order. When installing, note the following:
Renew seals (see the separate procedure).
Moisten with refrigerant oil to ease installation of refrigerant lines.
If the valve has been renewed, it must be programmed using
Vehicle diagnostic tester.
Using
Vehicle diagnostic tester
, initiate basic setting, then perform function "Charge refrigerant circuit".
Note
Always perform the basic setting
“Charge refrigerant circuit” using the
Vehicle diagnostic tester
, to make sure that all valves of the refrigerant circuit are opened. This is the only way to charge the complete circuit.
The
Vehicle diagnostic tester must not be disconnected from the vehicle during the entire extraction, evacuation and charging process.
If the component has been renewed due to a mechanical defect (e.g. wear), purge the refrigerant circuit.
Only start engine after refrigerant circuit has been assembled.
Only start engine when refrigerant circuits are charged.
Specified torque (see “Assembly overview – valve unit of heat pump”) (see the separate procedure) “Removing and installing high-voltage heater (PTC)
Z115
/ high-voltage heater (PTC)
J848”
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other VW procedures
- Heat exchanger for high-voltage battery VX63 with refrigerant shut-off valve for high-voltage battery heat exchanger N542
- Heat exchanger for high-voltage batteryVX63 with refrigerant shut-off valve for high-voltage battery heat exchanger N542
- Removing and installing refrigerant line between condenser, refrigerant shut-off valve 5N643 and refrigerant shut-off valve 1N696
- Removing and installing refrigerant line between reservoir, refrigerant shut-off valve 5N643 and valve unit of heat pump
- Removing and installing refrigerant shut-off valve 1 N696
- Removing and installing refrigerant shut-off valve 1N696
- Removing engine
- Removing and installing camshaft – VW Golf Cabriolet
- Adjusting valve timing – VW Passat B5
- Removing and installing camshafts – VW Passat B6
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com