🧭 Before you start

  • Replacement notes from the steps (read the conditions below): Renew seals. For versions, refer to Electronic parts catalogue. [Note: Moisten seals with refrigerant oil before installing.]
  • Also covered elsewhere: Electronic parts catalogue

Don't miss

  • For reasons of clarity, certain components are not shown in some of the illustrations.
  • One of the nuts is accessible from below.
  • Moisten seals with refrigerant oil before installing.

📋 Procedure

  1. Observe safety precautions when working on the high-voltage system Safety precautions when working on high-voltage system.
  2. Observe safety precautions Safety precautions when working on air conditioning systems.
  3. Observe safety precautions when working in the vicinity of high-voltage components Safety precautions when working in the vicinity of high-voltage components.
  4. Comply with notes Working on refrigerant circuit.
  5. Observe the risk rating of the high-voltage system Electric drive 00. Risk category of the high-voltage system.
  1. Now de-energise the high-voltage system Electric drive 93. De-energising the high-voltage system.
  2. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to extract the complete refrigerant from the circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.]
  1. Extract refrigerant with air conditioning service station. Comply with notes (see the separate procedure).
  2. If fitted, remove noise insulation under engine General body repairs, exterior 66. Noise insulation; Assembly overview - noise insulation.
  3. Remove front bumper cover General body repairs, exterior 63. Front bumper cover; Assembly overview - bumper cover.
  4. Remove front right headlight Electrical system 94. Headlight; Removing and installing headlight.
  5. Remove front part of front right wheel housing liner General body repairs, exterior 66. Wheel housing liner; Removing and installing front wheel housing liner.
  6. If necessary, remove engine cover panel 93Electric drive motor; Removing and installing engine cover panel.
  7. Before removing, mark connectors and hoses accordingly. [Note: For reasons of clarity, certain components are not shown in some of the illustrations.]
  1. Loosen clamps (1) to (7), and pull off coolant hoses.
  2. Disconnect connectors (1), (2), (3) and (4).
  3. Disconnect spacers on coolant hoses.
  4. Separate connectors (3) and (4).
  5. Unclip cable retainers for connectors (3) and (4) from bracket.
  6. Unscrew nut (2), and remove potential equalisation line.
  7. Unscrew nuts (5). [Note: One of the nuts is accessible from below.]
  1. Separate connector (1).
  2. Unscrew nuts (1).
  3. Carefully remove high-voltage heater (PTC)Z115 upwards together with coolant hoses.
  1. Unscrew nut (4).
  2. Separate connector (7).
  3. Remove bolts (5) and (8).
  4. Lay coolant expansion tank to one side.
  5. Remove bolt (3).
  6. Remove bracket (2)
  7. Unclip refrigerant line (1) from retainer (6).
  8. Remove refrigerant line (1).
  1. Renew seals. For versions, refer to Electronic parts catalogue. [Note: Moisten seals with refrigerant oil before installing.]
  1. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to charge the complete circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. If the component has been renewed due to a mechanical defect (e.g. wear), purge the refrigerant circuit.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.