TorqFix

Removing and installing air flow flap control motor V71 with potentiometer for air flow flap control motor G113: VW

Removing and installing air flow flap control motor V71 with potentiometer for air flow flap… Read available instructions and vehicle application notes.

22 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: VW Passat CC (357, 2008–2012), VW Passat B6 (3C, 2005–2010), VW CC (358, 2012–2017)

Don't miss

  • Mark connector to air recirculation flap control motor V113 (to avoid interchanging with connector to air flow flap control motor V71).
  • Before installing control motor, check mounting of air flow flap in intake duct and gear (C) (air flow flap is open, "“fresh air mode”").
  • After installing control motor, push gear (1) back onto shaft of air flow flap (in direction of arrow).
  • After installing air flow flap control motor V71, check operation of air flow flap.

📋 Procedure

  1. If necessary, switch on ignition, select "“defrost”" mode on the operating and display unit for Climatronic air conditioning system E87 (control motor is always set to "“fresh air mode”" in this position) and wait for control motor to reach "“fresh air mode”" end position.
  2. Switch off ignition.
  3. Remove glove compartment General body repairs, interior 68. Compartments/covers; Removing and installing glove compartment.
  4. Release catches (D) and (E) for retainer (A) on intake duct and remove retainer (A).
  5. Remove recirculated air flap control motor V113.
  6. Mark connector to air recirculation flap control motor V113 (to avoid interchanging with connector to air flow flap control motor V71).
  7. Remove control motor (A) from intake duct. [Note: The connection between the gears of the control motor and the air flow flap is designed so that the control motor can be removed without trouble only in the position "“fresh air mode”".If the control motor is in a different position and can no longer be moved, it must not simply be pulled off. First, the control motor must be released from its mounting points (B) with force. During this operation, ensure that gear (C) is not damaged.] [Note: The control motor is supplied as a replacement part in the position "“fresh air mode”". It can be pushed onto the gear of the fresh air and air recirculation flap only if gear (A) is at stop (B). If a control motor is removed in a different position or actuated before it is removed, it cannot be installed. If the gear (A) of the control motor is not at stop (B)"“fresh air mode”", proceed as follows:]
  1. Connect control motor to vehicle wiring harness.
  2. Switch on ignition.
  3. Wait until gear (A) of control motor has reached stop (B)"“fresh air mode”".
  4. Switch off ignition.
  5. Before installing control motor, check mounting of air flow flap in intake duct and gear (C) (air flow flap is open, "“fresh air mode”").
  6. Connect air flow flap control motor V71 to vehicle wiring harness (check that correct connector is used).
  7. Reach into intake opening for recirculated air mode and move fresh air / air recirculation flap (A) to "“fresh air mode”" position (air duct opening for recirculated air mode is closed).
  8. Insert control motor (B) in mountings (C) against direction of arrow and onto gear (D). [Note: In order for the gear on the control motor (A) to be pushed onto the gear for the air flow flap, the short tooth (C) of the control motor gear must align with the short gap between teeth (D) of the gear on the shaft of the air flow flap (D).]
  1. After installing control motor, push gear (1) back onto shaft of air flow flap (in direction of arrow).
  2. Install air recirculation flap control motor V113.
  3. Route wiring harness so that it cannot come into contact with any moving parts (e.g. actuating arm on control motor).
  4. Install retainer (A), paying particular attention to ensure guide of retainer (B) is properly inserted in support of air intake duct (C) and retainer is properly engaged in both catches (D) and (E). [Note: The positions of the air flow flap control motor V71 and air recirculation flap control motor V113 (and associated flaps) cannot be seen when the glove box is installed, so it is prudent to check their function before installing the glove compartment. If the two gears (on the air flow flap control motor V71 and the air flow flap) are installed in the wrong positions, it will be noticeable that the air flow flap will not reach its two end positions or the control motor does not run smoothly without catching.]
  1. Reinstall all parts in reverse order of removal. [Note: After installing air flow flap control motor V71, check operation of air flow flap.]
  1. Checking: with vehicle diagnostic tester
  2. Renewing: initiate basic setting using vehicle diagnostic tester.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com