  1. Observe safety precautions Safety instructions.
  2. Comply with notes Working on refrigerant circuit.
  3. Observe instructions when working on refrigerant circuit (see the separate procedure).
  4. Extract refrigerant using air conditioner service station before opening refrigerant circuit.
  5. Remove noise insulation under engine General body repairs, exterior 66. Noise insulation; Assembly overview - noise insulation.
  1. Remove poly V-belt 13Cylinder block (pulley end); Removing and installing poly V-belt.
  1. Unscrew bolts (3) and disconnect refrigerant lines (2) and (4) from air conditioner compressor (1).
  2. Disconnect connector (6) on air conditioner compressor (1).
  3. Unscrew hexagon bolts (5) and remove air conditioner compressor (1).
  1. Thoroughly clean the contact surfaces at the air conditioner compressor and holder.
  2. Insert dowel sleeves (arrows) into air conditioner compressor. [Note: Ensure that dowel sleeves are properly seated and that contact surfaces are clean. Improperly fitted dowel sleeves or dirty or damaged contact surfaces can cause deviations in alignment of air conditioner compressor and engine. In the course of operation, misalignment will result in damage to the air conditioner compressor. If the air conditioner compressor is renewed on account of specific problems (e.g. internal damage), the refrigerant circuit must be cleaned Air conditioning system - with refrigerant R134a.When it is removed, the air conditioner compressor contains an indeterminate amount of refrigerant oil. For this reason it is important to observe the notes on renewing the air conditioner compressor Air conditioning system - with refrigerant R134a.]
  1. Refer to notes on commissioning of air conditioning system after installation of air conditioner compressor Air conditioning system - with refrigerant R134a.
  2. After installing a new air conditioner compressor or filling with fresh refrigerant oil (e.g. after blowing out refrigerant circuit), turn AC compressor poly V-belt pulley 10 revolutions by hand before starting engine. This will prevent damage to the air conditioner compressor.
  3. Start engine with air conditioner compressor switched off (control lamp in AC button is off) and wait until idling speed is stable.
  4. Open dash panel vents.
  5. Set temperature to "“Lo”" on heater and air conditioning controlsEX21 or on temperature preselection.
  6. Switch on air conditioner compressor (control lamp in AC button lights up) and let it run for at least 5 minutes with engine at idling speed. [Note: The air conditioner compressor is driven permanently by the poly V-belt pulley (not fitted with a magnetic clutch).If an air conditioner compressor seizes, the overload protection separates from the air conditioner compressor shaft. The seizure can normally be detected by the bulges in the poly V-belt pulley. Another indication of a seizure is abraded rubber material around the poly V-belt pulley. The air conditioner compressor has an internal oil circuit to ensure that the air conditioner compressor is not damaged when the refrigerant circuit is empty. This means that approx. 40 to 50 cm3 of refrigerant oil remains in the air conditioner compressor. Only start engine when refrigerant circuits are charged. The engine may be started only when the refrigerant circuit is properly assembled. If, for example, the refrigerant lines are not connected to the air conditioner compressor and the engine is running, the compressor may heat up so much through internal warming that it will be destroyed. Air conditioning system compressor regulating valve N280 is not activated when the refrigerant circuit is empty and the air conditioner compressor idles with the engine. If it is necessary to start engine with an empty refrigerant circuit:The refrigerant circuit must be fully assembled. At least ¼ of the quantity of refrigerant oil specified for this refrigerant circuit must be in the air conditioner compressor. The engine speed must not exceed 2000 rpm. Run engine only as long as absolutely necessary, max. 10 minutes.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.