TorqFix

508 - DW10FD — PEUGEOT

508 - DW10FD — Peugeot. 49 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

49 steps 1 engine code

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Don't miss

  • Caution! The temperature of the engine and exhaust will increase significantly
  • Caution! Note the additive hazard warnings
  • Do not re-use the drained fluid or fluid from opened containers
  • Ensure the filling container is closed and lower than the additive tank before connecting
  • Ensure the container remains horizontal and no air can enter the filler pipe

🔧 Engine codes recorded for this source

📋 Procedure

Preparation and removal

  1. Caution! The temperature of the engine and exhaust will increase significantly
  2. Without diagnostic tool:
  3. Check the oil level
  4. Check the coolant level
  5. Note: The fuel tank should contain at least 20 litres of fuel
  6. Remove the underbody cover
  7. Start the engine
  8. Run the engine until warm
  9. Connect the diagnostic tool
  10. Note: Plug the ends of the fuel lines
  11. Delete all the fault codes
  12. Caution! Note the additive hazard warnings
  13. Follow the instructions on the screen of the diagnostic tool
  14. Remove the additive tank
  15. Note: Do not re-use the drained fluid or fluid from opened containers
  16. Disconnect the filler pipe
  17. Run the engine at idle speed
  18. Wait until the engine has cooled down
  19. Stop the engine
  20. Empty the additive tank
  21. Collect the escaping fluid in a measuring container
  22. Check the additive level
  23. Raise the vehicle
  24. Remove the underbody cover
  25. Disconnect the filler pipe

Installation and checks

  1. Connect the additive tank filling kit filler pipe to the additive tank filler pipe
  2. Refit the additive tank
  3. Installation is in the reverse order of removal
  4. Refill the additive tank
  5. Refit the cover
  6. Reprogram the additive pump
  7. Use the diagnostic tool
  8. Using the diagnostic tool:
  9. Check the additive level
  10. Connect the overflow container pipe to the additive tank
  11. Note: Ensure the filling container is closed and lower than the additive tank before connecting
  12. Raise the filling container above the additive tank
  13. Note: Ensure the container remains horizontal and no air can enter the filler pipe
  14. Open the filling container valve
  15. Close the valve when fluid is escaping through the overflow pipe
  16. Lower the filling container
  17. Open the valve until the remaining fluid returns to the filling container
  18. Remove the overflow pipe
  19. Disconnect the additive tank filling kit filler pipe from the additive tank filler pipe
  20. Reconnect the filler pipe
  21. Remove the filling and overflow container
  22. Refit the cover
  23. Reset the additive system
  24. Use the diagnostic tool

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.