TorqFix

Testing intake air temperature sender (vehicles with intake manifold change-over function): Audi

Testing intake air temperature sender (vehicles with intake manifold change-over function) — Audi. Read available instructions and vehicle application notes.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

ARM
Note:

In vehicles with intake manifold change-over function, the intake air temperature sender (-G42) is integrated in the air mass meter. The sender therefore no longer exists as a separate component on the engine.

Connect fault reader V.A.G 1551 (V.A.G 1552). Then switch on ignition and select engine control unit with "Address word 01".
(Connecting fault reader and selecting engine control unit
=> Page
01-4.)

Rapid data transfer
HELP
Select function XX
Indicated on display:

Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.

Read measured value block
HELP
Input display group number XXX
Indicated on display:

Press keys 0, 0 and 5 for "Display group number 5" and confirm entry with Q key.

Read measured value block 5
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)

Functional check of sender

Note intake air temperature figure in display zone 4.

Display · Cause · Continuation of check
60 °C · Open circuit or short to positive · => Page 28-13
Short to earth
Approx. ambient temperature1) · --- · => Page 28-15

1)
If a temperature is displayed which deviates greatly from the ambient temperature of the sender, check sender wiring for contact resistance.

Continuation of check:

Switch off ignition.
Connect test box V.A.G 1598/22 to control unit wiring harness.

Pull 4 pin connector -1- off air mass meter -2-.
Check wiring between test box and 4 pin connector for open circuit using current flow diagram.
Contact 2 + socket 12
Contact 4 + socket 9 (on vehicles with data bus system /ESP; on other vehicles: socket 54) resistance: max. 1.5ω
Additionally check for short circuits between the wires
Specification: ∞ω

If no fault in wire is detected:

Test resistance between contacts 2 and 4 of sender.

Scale A shows resistance values for temperature range 0...50 °C and scale B the values for temperature range 50...100 °C.

Examples:

30 °C corresponds to a resistance from 1500...2000 ω
80 °C corresponds to a resistance from 275...375 ω

If the specification is not obtained:

Replace air mass meter (G70) together with intake air temperature sender (G42).

Continuation of check when display = ambient temperature:

Remove intake hose between air mass meter and throttle valve control part.
Note intake air temperature value in display zone 4.

Spray sender -arrow- with commercial chilling agent whilst observing the temperature value. The temperature value must decrease.
Press ⇒key.
Press keys 0 and 6 for the function "End output" and confirm entry with the Q key.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.