Renewing selector shaft oil seal: Audi A3 (8V)
Renewing selector shaft oil seal — Audi A3 (8V). 21 source steps. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8V, 2012–2020)
- Opens: coolant
Don't miss
- For greater clarity, the illustration shows the installation position with the high-voltage components removed.(Item 3) can be disregarded.
- Risk of damage to selector lever cable.Do not press selector lever cable towards rear out of cable support bracket.Do not bend or kink the selector lever cable. — Remove nut (1).
- Risk of damage to running surface of selector shaft.Apply screwdriver with care. — Push a small screwdriver through the oil seal and pull it out.
📋 Procedure
- ⚠ High voltage can cause fatal injury. Danger of severe or fatal injuries from electric shock. Have the high-voltage system de-energised by a "“high-voltage technician (HVT)”".All work on the de-energised high-voltage system must be performed by an "“electrically instructed person (EIP)”". — De-energise high-voltage system Engine, mechanics 93. De-energising high-voltage system.
- Remove engine cover panel Engine, mechanics 10. Engine cover panel; Removing and installing engine cover panel.
- Drain coolant from engine Engine, mechanics 19. Cooling system/coolant; Draining and filling cooling system.
- Drain coolant from cooling system for high-voltage components Engine, mechanics 19. Cooling system/coolant; Draining and filling cooling system.
- Unplug electrical connector (3).
- Release catches (2) with a small screwdriver (arrow) and disengage coolant expansion tank (1) from bracket.
- Unscrew nuts (2) and detach bracket (1).
- Lift retaining clip (1) and loosen hose clip (2). Disconnect coolant hoses and press hoses to side. [Note: For greater clarity, the illustration shows the installation position with the high-voltage components removed.(Item 3) can be disregarded.]
- Release hose clips (arrows), disconnect coolant hoses and press hoses to side.
- Detach retaining clip (2).
- Unclip and remove securing clip (1).
- Press selector lever cable off gearbox selector lever.
- ⚠ Risk of damage to selector lever cable. Do not press selector lever cable towards rear out of cable support bracket. Do not bend or kink the selector lever cable. — Remove nut (1).
- Carefully pry gearbox selector lever (2) off selector shaft.
- ⚠ Risk of damage to running surface of selector shaft. Apply screwdriver with care. — Push a small screwdriver through the oil seal and pull it out.
- Lightly lubricate outer circumference and sealing lips of new oil seal with gear oil.
- Pack space between sealing lip and dust lip (arrow) half full with sealing grease Electronic parts catalogue.
- Drive in oil seal onto stop using socket (15 mm) (item 1); take care to keep seal straight when installing.
- Fit gearbox selector lever (2) on selector shaft and tighten nut (1).
- Press selector lever cable onto gearbox selector lever and adjust selector lever cable (see the separate procedure).
- ⚠ High voltage can cause fatal injury. Danger of severe or fatal injuries from electric shock. Have the high-voltage system re-energised by a "“high-voltage technician (HVT)”". — Re-energising the high-voltage system Engine, mechanics 93. Re-energising high-voltage system.
📐 9 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- 6-speed manual gearbox 0A2, front-wheel drive — Renewing oil seal for selector shaft with gearbox installed
- 6-speed manual gearbox 0A3, four-wheel drive — Renewing oil seal for selector shaft with gearbox installed
- Renewing oil seal for selector shaft – Audi A6 C6
- Renewing oil seal for selector shaft with gearbox installed
- Renewing oil seal for selector shaft (with gearbox installed in vehicle)
- Servicing multitronic 01J and 0AN — Renewing oil seal for selector shaft
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.