📋 Procedure

  1. Unclip cover caps.
  2. Unscrew nuts (arrows) and detach engine cover panel. Also pull out dipstick if necessary.
  3. Remove insulation beneath cover panel (if fitted).
  4. Remove Lambda probe (repair group 23).
  5. Vehicles with auxiliary heater: remove bolts (arrows) securing exhaust pipe for auxiliary/additional heater to noise insulation.
  6. Open quick-release fasteners (1 … 3) and take off front and rear noise insulation.
  7. Remove noise insulation (1) in wheel housing (right-side).
  8. Remove bolts (1) and (2) on bracket for front exhaust pipe.
  9. Unscrew nuts (arrows). [Note: Disregard (item 1).]
  1. Disconnect exhaust system at clamp (arrow).
  2. Detach front exhaust pipe from threaded pins on particulate filter.
  3. Remove nuts (3).
  4. Remove bolts (arrows).
  5. Detach intake manifold with exhaust gas recirculation cooler and push slightly to one side, leaving coolant hoses (1) and (2) connected.
  6. Unscrew threaded pin (1) from exhaust manifold.
  7. Unscrew union nut (2) and push pipe slightly to one side.
  8. Take electrical connector (1) for temperature sender before particulate filter G506 out of bracket.
  9. Unplug electrical connector and move wiring clear.
  10. Unplug electrical wiring at exhaust gas pressure sensor 1G450(item 2).
  11. Unscrew nut and detach exhaust gas pressure sensor 1G450 from bracket.
  12. Leave hoses connected and move exhaust gas pressure sensor 1G450 clear towards bottom of vehicle.
  13. Unscrew nuts (1 ... 3) and lift out particulate filter. [Note: Renew gaskets and self-locking nuts. Hose connections and hoses for charge air system must be free of oil and grease before assembly. Secure all hose connections with the correct type of hose clips (same as original equipment) Electronic parts catalogue. Fit all cable ties in the original positions when installing.]
  1. Install temperature sender before particulate filter G506.
  2. Install front exhaust pipe (see the separate procedure).
  3. Install Lambda probe (repair group 23).
  4. Align exhaust system so it is free of stress (see the separate procedure).
  5. After renewing particulate filter, perform "Adaption" in "“Guided Fault Finding”" mode (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.