Removing and installing Lambda probe G39 (before catalytic converter at front right): Audi A8 D3 (4E) (BHT, BSB, BTE)
Removing and installing Lambda probe G39 (before catalytic converter at front right) — Audi A8 D3… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A8 D3 (4E, 2002–2010)
Don't miss
- Ignore other items.
📋 Procedure
- Detach electrical connector (1) for air mass meter G70.
- Detach air intake hose (4) from intake manifold.
- Unhook bracket for connectors (2) and (3) at top section of air cleaner housing.
- Remove bolts (arrows).
- Detach top section of air cleaner housing (right-side).
- Remove air duct (1).
- Remove bolts (arrows).
- Remove bottom section of air cleaner housing (right-side).
- Unplug electrical connector (8) for Lambda probe G39. [Note: Ignore other items.]
- Move electrical wiring to Lambda probe clear.
- Unscrew Lambda probe G39(arrow 2) using Lambda probe open ring spanner set 3337. [Note: Threads of new Lambda probes are already coated with assembly paste; the paste must not get into the slots on the probe body. If reinstalling the old Lambda probes, coat the threads with high-temperature paste Parts catalogue. The paste must not get into the slots on the probe body. Fit all cable ties in the original positions when installing. When installing, the Lambda probe wires must always be reattached at the same locations to prevent them from coming into contact with the exhaust pipe.]
📐 4 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking ageing of lambda probes before catalytic converter (on vehicles which conform to emission standard EU III)
- Checking Lambda probe and Lambda control before catalytic converter
- Checking lambda probe and lambda regulation before catalytic converter
- Checking lambda probe heating before catalytic converter
- Checking lambda probe heating for lambda probe before catalytic converter
- Checking Lambda probe heating Z19 for Lambda probe before catalytic converter
- Removing and installing intake manifold (top section) – Audi
- Removing and installing fuel gauge sender 4G393 (tubular sender, right-side)
- Checking fuel system pressurisation pump G6 (left-side) - electrical test
- Checking delivery rate of fuel pumps - vehicles with 8-cylinder engine
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.