Removing and installing intake manifold flap motor V157 or intake manifold flap 2 motor V275: vehicles with engine codes BMK, BPP, BSG, BNG, ASB — Audi A6 C6 (4F)
Removing and installing intake manifold flap motor V157 or intake manifold flap 2 motor V275… Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A6 C6 (4F, 2004–2011)
Don't miss
- If the following appears on the display, an incorrect software version has been loaded:1. START2. NEXTIf this is the case, download the correct software version from the "“Audi ServiceNet”" under "“Workshop Equipment”".
- "S" means specified value"I" means actual value
- Disregard items (2, 3 and 4).
- Power supply for testerVAS 6395/1 must remain connected. — Unscrew connecting piece for air intake hose (pulsation damper) (arrows) from turbocharger.
- Allow thread-forming bolt to engage in existing thread on intake manifold. Then tighten bolts to torque.Torx bolt: 6.5 NmHexagon socket head bolts, 9 Nm
📋 Procedure
- Remove engine cover panel (see the separate procedure).
- Unplug electrical connector (1) at air mass meter G70.
- Remove air intake hose. To do so, release hose clip (2) and clamps (arrows).
- Open cover (arrow) above positive terminal.
- Connect tester VAS 6395/1 with connection lead VAS 6395/4-2 to positive terminal "“+”" and negative terminal "“–”". [Note: If the following appears on the display, an incorrect software version has been loaded:1. START2. NEXTIf this is the case, download the correct software version from the "“Audi ServiceNet”" under "“Workshop Equipment”".]
- ⚠ Risk of damage to intake manifold flap motor. Before continuing, check whether the correct software version is loaded in the tester VAS 6395/1. To do so, proceed as follows: — Unplug electrical connector for intake manifold flap motor.
- Connect connection lead VAS 6395/4-2 to intake manifold flap motor and tester VAS 6395/1.
- To continue, press v button (item 4). [Note: "S" means specified value"I" means actual value]
- Unplug electrical connectors for tester VAS 6395/1.
- To do so, proceed as follows:
- To continue, press v button (item 4).
- Press ↓ button (item 6).
- To continue, press v button (item 4).
- By pressing buttons ↑(item 5) and ↓(item 6), adjust intake manifold flap motor in such a way that coupling rod can be accessed easily for removal.
- Unclip coupling rod (1) from intake manifold flap motor. [Note: Disregard items (2, 3 and 4).]
- To continue, press v button (item 4).
- ⚠ Power supply for tester VAS 6395/1 must remain connected. — Unscrew connecting piece for air intake hose (pulsation damper) (arrows) from turbocharger.
- If fitted, take electrical connector (arrow) for exhaust gas temperature sender 1G235 out of bracket.
- Disconnect connection lead VAS 6395/4-2(item 3) from intake manifold flap motor.
- Remove bolts (2) and (4).
- Detach old intake manifold flap motor.
- Install new intake manifold flap motor in reverse order of removal and clip coupling rod on. [Note: Allow thread-forming bolt to engage in existing thread on intake manifold. Then tighten bolts to torque. Torx bolt: 6.5 NmHexagon socket head bolts, 9 Nm]
- Connect connection lead VAS 6395/4-2 to intake manifold flap motor.
- To confirm that a new intake manifold flap motor has been installed, press v button (item 4).
- To continue, press v button (item 4).
- To continue, press v button (item 4).
- To continue, press v button (item 4).
- To continue, press v button (item 4).
- To confirm, press v button (item 4).
- Unplug electrical connectors for tester VAS 6395/1. [Note: Connection for air hose (pulse damper) must be free of oil and grease when installing. Tightening torque: 9 Nm]
Other AUDI procedures
- Removing and installing intake manifold flap motor V157/intake manifold flap 2 motor V275, performing adaption - vehicles with engine codes BUG and BUN only
- Removing and installing intake manifold flap motor V157 or intake manifold flap 2 motor V275
- Removing and installing intake manifold flap motor V157 - vehicles with engine codes AZV, BKD
- Removing and installing intake manifold flap motor V157/intake manifold flap 2 motor V275, performing adaption - vehicles with engine codes BUG and BUN only
- Removing and installing intake manifold flap motor V157 – Audi
- Removing and installing intake manifold flap motor V157 with intake manifold flap potentiometer G336
- Removing and installing upper coolant pipe
- Checking return flow rate of injectors (piezo injectors) at starting speed
- Removing and installing turbocharger (engine code BMK)
- Removing and installing metal glow plugs
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.