Models recorded for this source: Audi A4 B6/B7 (8E), Audi A4 Cabriolet B6/B7 (8H)
- Replacement notes from the steps (read the conditions below): When renewing engine control unit, select diagnosis object "“Renew engine control unit”" in "“Guided Fault Finding”". Use new shear bolts. Activate engine control unit in "“Guided Fault Finding”" under diagnosis option "“Replace engine control unit”".
Don't miss
- Then use hot air blower to heat the thread of the locking plate into which shear bolts have been screwed. This step reduces inhibiting action of locking fluid on shear bolt threads and makes it easier to unscrew these bolts.
- When the connectors are unplugged from the engine control unit, the learnt values are erased but the contents of the event memory remain intact.
- Protective housing must be screwed back on engine control unit.
📋 Procedure
- When renewing engine control unit, select diagnosis object "“Renew engine control unit”" in "“Guided Fault Finding”".
- Switch off ignition and remove ignition key.
- Detach rubber seal from plenum chamber cover in direction of (arrow).
- Detach plenum chamber cover (1) towards the front.
- Lever off both cover caps (3) with a screwdriver.
- Loosen hexagon nuts (4) several turns.
- Loosen wiper arms (2) from wiper shafts by tilting slightly.
- Remove hexagon nuts completely and take off wiper arms.
- Pull off retaining clips (1) and detach cowl panel grille (5).
- Remove cover for electronics box in plenum chamber (arrows).
- Carefully lever out the retaining strap using a screwdriver (arrow) from engine control unit with protective housing (4).
- Turn engine control unit (1) with protective housing (4) towards engine compartment so that locking plate (2) becomes visible.
- Place a clean cloth beneath the engine control unit for protection.
- ⚠ The following procedure must be followed exactly to prevent any damage (burning) to wiring, connectors, insulation and control units. Observe operating instructions for hot air blower. — Select settings on hot-air blower as shown in illustration, i.e. set temperature potentiometer (2) to maximum heat output and two-stage air flow switch (3) to position "“3”". [Note: Then use hot air blower to heat the thread of the locking plate into which shear bolts have been screwed. This step reduces inhibiting action of locking fluid on shear bolt threads and makes it easier to unscrew these bolts.]
- ⚠ Heating the thread of the locking plate also heats up the shear bolts and parts of the metal housing. Take care to avoid burns. It is also important to ensure that only the thread is heated and none of the surrounding components if at all possible. These should be covered if necessary. — Direct nozzle (1) of hot air blower towards thread of locking plate to enable nozzle to "“surround”" thread. Allow nozzle to rest on upper end of metal housing.
- Switch on hot air blower and heat thread for about 20 to 25 seconds.
- Then grasp head of bolt (2) with vice-grip pliers (1) and unscrew shear bolt in direction of arrow.
- Repeat the procedure for the second shear bolt. Be particularly careful here, as this shear bolt is in the immediate vicinity of control unit connector.
- Release multi-pin connectors and disconnect from engine control unit. [Note: When the connectors are unplugged from the engine control unit, the learnt values are erased but the contents of the event memory remain intact.]
- Remove engine control unit.
- Protective housing must be screwed back on engine control unit.
- Clean threaded holes for shear bolts to remove any residue from locking fluid. This can be done using a thread tap.
- Use new shear bolts.
- Activate engine control unit in "“Guided Fault Finding”" under diagnosis option "“Replace engine control unit”".
📐 6 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking compression - engine codes AVB, AVF and AWX – Audi
- Removing and installing intake manifold - engine codes AVB, AVF and AWX
- Removing and installing turbocharger- engine codes AVB, AVF, AWX and BKE
- Checking exhaust gas recirculation valve N18 - vehicles with engine code letters AVF, AWX
- Removing and installing bottom coolant pipe - vehicles with engine code letters AVF, AWX
- Removing and installing catalytic converter with exhaust pipe - vehicles with engine code letters AVF, AWX
- Draining fuel tank – Audi Q5
- Removing and installing particulate filter - vehicles with manual gearbox
- Checking fuel pump (electrical test)
- Removing and installing coolant pipe (top) – Audi A8 D3
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.