Draining fuel tank (natural gas): Audi A3 (8V) (CPWA)

Draining fuel tank (natural gas) — Audi A3 (8V) (CPWA). 47 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

47 steps 1 engine code

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8V, 2012–2020)

  • Replacement notes from the steps (read the conditions below): Check seal (3) for damage and renew if necessary.
  • Also covered elsewhere: IDE06792 Tank pressure sensor Dissipate pressure in high-pressure pipe

Don't miss

  • Discharging must be performed outdoors.Ensure that there are no ignition sources or naked flames in the vicinity of the vehicle and the tank.Danger of explosion! — Observe safety precautions Safety precautions.
  • The fuel tank shut-off valve must be flush with the gearbox support T40173.The pipe connection of the fuel tank shut-off valve must face downwards when the natural gas tank is attached.
  • Screw adapter on hand-tight; do not use pliers or any other tools.
  • The magnetic release tool T10349 must remain on the valve during the entire discharging process.This prevents the valve from sticking.
  • If leak cannot be repaired, gas discharge tube must not be used.

🔧 Engine codes recorded for this source

📋 Procedure

  1. ⚠ Discharging must be performed outdoors. Ensure that there are no ignition sources or naked flames in the vicinity of the vehicle and the tank. Danger of explosion! — Observe safety precautions Safety precautions.
  2. Observe rules for cleanliness Rules for cleanliness.
  3. Observe safety precautions when working on the natural gas system Safety precautions when working on the natural gas system.
  4. Check pressure of natural gas system.
  5. To do so, connect (see the separate procedure).
  6. Switch on ignition.
  7. Connect vehicle diagnostic tester and begin self-diagnosis with ODIS.
  1. Select and confirm engine code CPWA.
  2. ⇒ 01 - Engine electronics
  1. ⇒ IDE06792 Tank pressure sensor
  2. Dissipate pressure in high-pressure pipe (see the separate procedure).
  3. Disconnect battery Electrical system 27. Battery; Disconnecting and connecting battery.
  4. Remove corresponding tank (see the separate procedure).
  5. Align adjustable mountings of gearbox support T40173 with tank and tighten them.
  6. To tighten adjustable mountings properly, pull lever (1) downwards and adjust its position so that tank can be tightened securely. [Note: The fuel tank shut-off valve must be flush with the gearbox support T40173.The pipe connection of the fuel tank shut-off valve must face downwards when the natural gas tank is attached.]
  1. ⚠ It is very important that the tank is secured tightly to the engine and gearbox jack. Before starting work, make sure that the tank is properly secured to prevent it from falling. No work can be performed on the tank unless it is secured properly. — Place tank (1) on gearbox support T40173 (as illustrated); pipe connection must face downwards and fuel tank shut-off valve must be flush with gearbox support T40173.
  2. Secure tank (1) with tensioning strap T10523 to prevent it from falling.
  3. Attach buckles of tensioning straps so that they are offset as illustrated.
  4. Secure tank (1) to gearbox support T40173 using both tensioning straps T10523.
  5. When securing tank, take care not to damage its surface.
  6. If necessary, protect tank surface using suitable workshop materials.
  7. Secure bracket VAS 523 001/6 to gearbox support T40173, as shown in illustration (arrows).
  8. Insert gas discharge tube VAS 523 001/1 in guide (arrow) on bracket VAS 523 001/6.
  9. Screw suitable adapter VAS 523 001 onto gas discharge tube (4).
  10. Check that seal (3) is correctly seated.
  11. Screw adapter (2) onto fuel tank shut-off valve(1).
  12. Screw adapter on hand-tight; do not use pliers or any other tools.
  13. Unscrew plug (arrow) from fuel tank shut-off valve(1).
  14. Unscrew and remove nut (arrow) from fuel tank shut-off valve(1).
  15. Detach magnetic coil (2) from fuel tank shut-off valve(1) in direction of (arrow).
  16. Fit magnetic release tool T10349 onto valve (1). [Note: The magnetic release tool T10349 must remain on the valve during the entire discharging process. This prevents the valve from sticking.]
  1. Apply hand wheel T50026 to manual shut-off mechanism on fuel tank shut-off valve.
  1. ⚠ A protected area must be set up in the immediate vicinity of the tank; this area must not be entered while the tank is being discharged. Leave the protected area after opening the manual shut-off valve. Inhaling natural gas can cause damage to the respiratory tract. When no more natural gas escapes from the tank, the residual pressure must be checked (see the separate procedure). — Use hand wheel T50026 to open fuel tank shut-off valve carefully until natural gas escapes.
  2. Close fuel tank shut-off valve again after 1 to 2 seconds.
  3. Check connection points between gas discharge tube (4) and fuel tank shut-off valve(1) for leaks.
  4. To do so, use gas leak detector VAS 6227 and commercially available leak detection spray.
  1. Check seal (3) for damage and renew if necessary.
  2. Check connection between gas discharge tube (4) and fuel tank shut-off valve(1) for dirt, and tighten if necessary.
  3. If leak cannot be repaired, gas discharge tube must not be used.
  1. Use hand wheel T50026 to open fuel tank shut-off valve(1) carefully until natural gas escapes.
  2. Carefully open fuel tank shut-off valve as far as possible without triggering »pipe break safety mechanism«.
  3. Fuel tank shut-off valve must not be opened all the way. [Note: Depending on the tank pressure, it may be possible to open the fuel tank shut-off valve all the way. Opening the valve all the way triggers a pipe break safety mechanism, after which only a minimal amount of natural gas can escape.]
  1. To deactivate the pipe break safety mechanism, the pressure must be equalised by closing the manual shut-off valve.
  2. Close valve and open it again (but not as far as before).
  3. The valve can be opened all the way again after approx. 2 minutes.
  1. When no more natural gas escapes from the fuel tank, the manual shut-off valve must be closed again.
  2. Check residual pressure to ensure that tank is sufficiently empty (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.