TorqFix

Checking function of variable valve timing: Audi A4 B5 (8D)

Checking function of variable valve timing — Audi A4 B5 (8D). 19 source steps and 4 tables. Check the document conditions against your vehicle.

19 steps 16 engine codes 4 original source tables Showing one source document; this title group contains 9 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A4 B5 (8D)

Don't miss

  • Engine running at idling speed.

🔧 Engine codes recorded for this source

📋 Procedure

  1. ⚠ Test equipment must always be secured on the rear seat and operated from that position by a second person. If test and measuring instruments are operated from front passenger's seat and the vehicle is involved in an accident, the person sitting in this seat could be seriously injured when the airbag is triggered. — Start engine and run at idling speed.
  1. From the list (1) select diagnostic function "“08 - Read measured value block”".
  1. Use keypad (2) to enter "“27”" for "“Display group number 027”" and confirm by touching the Q key. [Note: Engine running at idling speed.]
  1. Check specifications in display zones (1), (3) and (4).
  1. Perform test drive.
  2. Check specifications in display zones (1), (3) and (4).
  1. Exit function "“08 - Read measured value block”" by pressing the ← key.
  2. Press "“06 - End output”".
  3. Switch off ignition.
  1. Check the camshaft control valves (see the separate procedure).
  1. From the list (1) select diagnostic function "“08 - Read measured value block”".
  1. Use keypad (2) to enter "“90”" for "“Display group number 090”" and confirm by touching the Q key. [Note: Engine running at idling speed.]
  1. Check specifications in display zones (2), (3) and (4).
  1. Perform test drive.
  2. Check specifications in display zones (2), (3) and (4).
  1. Exit function "“08 - Read measured value block”" by pressing the ← key.
  2. Press "“06 - End output”".
  3. Switch off ignition.
  1. Check the camshaft control valves (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.