Checking fuel system pressurisation pump G6 — vehicles with 5-cyl. engine — Audi A3 (8V). 28 source steps. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8V, 2012–2020)
- Opens: fuel
Don't miss
- Disregard (item 3).
- Disregard (item 2).
- Risk of fuel escaping.Cut-off valve (C) must be closed.The lever should point perpendicular to direction of flow. — Connect vehicle diagnostic tester.
- From this point on, do not turn adjuster screw (1).
- To find the precise cause of the fault, a pressure test must be performed on the fuel supply line as described below.
🔧 Engine codes recorded for this source
📋 Procedure
- Observe test conditions (see the separate procedure).
- Release and open tank flap.
- Clean area around fuel filler neck.
- Remove filler cap (2) for fuel filler neck (1). [Note: Disregard (item 3).]
- ⚠ Risk of injury - fuel system operates under high pressure. To reduce the pressure in the fuel system, wrap a clean cloth around the connection and carefully loosen the connection. — Disconnect fuel line (1). Disconnecting plug-in connectors [Note: Disregard (item 2).]
- Connect pressure tester VAS 6550 to fuel supply line with hose VAS 6550/2.
- Attach pressure control valve VAS 6550/4 and hold end of hose into fuel-resistant measuring container.
- Switch on pressure tester VAS 6550(item 1) by pressing On/Off button. [Note: To measure the fuel delivery rate, pressure must first be built up in the fuel line; the fuel pump must then operate against this pressure during the measurement. This pressure can be built up using the pressure control valve VAS 6550/4 as follows:]
- Open cut-off valves (A and B).
- ⚠ Risk of fuel escaping. Cut-off valve (C) must be closed. The lever should point perpendicular to direction of flow. — Connect vehicle diagnostic tester.
- Switch on the ignition and select the following menu options on the vehicle diagnostic tester:
- Press Start: The fuel pump will start running.
- Build up pressure in fuel system by turning adjuster screw (1) on pressure control valve VAS 6550/4 until correct pressure is reached.
- From this point on, do not turn adjuster screw (1).
- Press Stop.
- Drain measuring container.
- For measurement, press Start again and let fuel pump run for 15 seconds.
- Press Stop after 15 seconds.
- Check amount of fuel delivered in measuring container. [Note: To find the precise cause of the fault, a pressure test must be performed on the fuel supply line as described below.]
- Switch on pressure tester VAS 6550(item 1) by pressing On/Off button.
- Open cut-off valves (A and B).
- ⚠ Risk of fuel escaping. Cut-off valve (C) must be closed. The lever should point perpendicular to direction of flow. — Press Start on vehicle diagnostic tester display to start the fuel pump.
- When fuel emerging is free of bubbles, close cut-off valve (B) to allow fuel pressure to build up.
- Read fuel pressure off pressure tester VAS 6550:
- Check system for leaks and check residual pressure by watching drop in pressure on pressure tester VAS 6550: [Note: Before removing the pressure tester (1), release the fuel pressure by opening the cut-off valves (B, C) and allowing fuel to drain off into a measuring container.]
- Detach pressure tester VAS 6550 together with connection leads.
- Connect fuel supply line, making sure it engages audibly.
- Press fuel supply line in again and then pull to check that plug-in connector is correctly engaged.
Other AUDI procedures
- Checking fuel system pressurisation pump G6 - A5 from model year 2012 onwards, A4 with 4-cyl. and 6-cyl. engines from model year 2013 onwards, RS 5 from model year 2012 onwards, RS 4
- Checking fuel system pressurisation pump G6 - vehicles with 4-cyl. engine
- Checking current draw of fuel system pressurisation pump G6
- Checking current draw of fuel system pressurisation pump G6, engine codes CAAA, CAAB, CAAC, CAAD, CAAE, CCHA, CCHB, CFCA
- Checking delivery pressure of fuel system pressurisation pump G6
- Checking delivery pressure of fuel system pressurisation pump G6, engine codes AXD, AXE, BLJ, BNZ, BPC
- Removing and installing oil pressure switch F1
- Removing and installing fuel line for auxiliary/supplementary heater
- Removing and installing injectors, direct injection
- Removing and installing engine support – Audi 1.6 TDI
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.