Models recorded for this source: Audi A6 C6 (4F, 2004–2011)
- Special tools named: V.A.G 1598/39
- Replacement notes from the steps (read the conditions below): Renew fuel system diagnostic pumpV144.
Don't miss
- The running sound of the diagnostic pump can be heard at the wheel housing (rear left).
- The diagnostic pump is supplied with voltage via the Motronic current supply relay J271.
📋 Procedure
- From menu (1), select "“Self diagnosis”" system and press → key to activate function.
- From menu (1), select vehicle system "“01 - Engine electronics”" and press → key to activate function.
- From menu (1), select function "“005 - Final control diagnosis”" and press → key to activate function.
- Press → key repeatedly until fuel system diagnostic pump V144 is activated. [Note: The running sound of the diagnostic pump can be heard at the wheel housing (rear left).]
- Press ← key to exit from function "“005 - Final control diagnosis”".
- Select function "“022 - End output”".
- Switch off ignition.
- Remove fuel system diagnostic pump V144 and disconnect electrical connector.
- Connect up hand-held multimeter V.A.G 1526C to measure resistance as follows:
- Renew fuel system diagnostic pump V144.
- Check voltage supply of diagnostic pump (see the separate procedure). [Note: The diagnostic pump is supplied with voltage via the Motronic current supply relay J271.]
- Connect voltage tester V.A.G 1527B as follows:
- Operate the starter briefly.
- Use current flow diagram to check for open circuit in wiring from contact (3) via fuse to Motronic current supply relay J271.
- Eliminate open circuit in wiring (refer to current flow diagram).
- Connect voltage tester V.A.G 1527B as follows:
- Start final control diagnosis (see the separate procedure).
- Press → key repeatedly until fuel system diagnostic pump V144 is activated.
- Press ← key to exit from function "“005 - Final control diagnosis”".
- Select function "“022 - End output”".
- Switch off ignition.
- Connect the test box V.A.G 1598/42 to wiring harness with adapter lead V.A.G 1598/39-1 or adapter lead V.A.G 1598/39-2. Connect earth clip of test box to negative terminal of battery. The instructions for performing the individual tests indicate whether or not the engine control unit itself also needs to be connected to the test box.
- ⚠ Electronic components are susceptible to damage. Select the appropriate measuring range before connecting the test leads and observe test requirements. — Check for open circuit and short to positive or earth in the following wiring:
- Repair open circuit or short circuit in wiring (refer to current flow diagram).
- Renew fuel system diagnostic pump V144.
- Observe notes on procedures required after connecting engine control unit (repair group 24).
- Switch off ignition.
- Connect the test box V.A.G 1598/42 to wiring harness with adapter lead V.A.G 1598/39-1 or adapter lead V.A.G 1598/39-2. Connect earth clip of test box to negative terminal of battery. The instructions for performing the individual tests indicate whether or not the engine control unit itself also needs to be connected to the test box.
- ⚠ Electronic components are susceptible to damage. Select the appropriate measuring range before connecting the test leads and observe test requirements. — Check for open circuit and short to positive or earth in the following wiring:
- Repair open circuit or short circuit in wiring (refer to current flow diagram).
- Observe notes on procedures required after connecting engine control unit (repair group 24).
📐 6 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking fuel system diagnostic pump V144 - vehicles with FSI engine
- Checking fuel system diagnostic pump V144 – Audi TT Mk1 1.8
- Checking fuel system diagnostic pump V144 - vehicles with 8-cylinder MPI engine
- Checking fuel system diagnostic pump V144 – Audi 1.8
- Checking fuel system diagnostic pump V144 - vehicles with 8-cylinder MPI engine
- Bleeding fuel system – Audi A4 Cabriolet B6/B7 / A4 B6/B7
- Checking fuel pump (electrical test)
- Removing and installing intake manifold (bottom section) with fuel rail
- Removing and installing coolant pipe (top) – Audi A8 D3
- Removing and installing front exhaust pipe (right-side) with catalytic converter - vehicles with multitronic gearbox
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.