TorqFix

Removing and installing intake manifold (bottom section) with fuel rail: Audi Q7 (4M) (CREC)

Removing and installing intake manifold (bottom section) with fuel rail — Audi Q7 (4M) (CREC). Read available instructions and vehicle application notes.

22 steps 1 engine code Showing one source document; this title group contains 35 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi Q7 (4M, 2015–)

  • Replacement notes from the steps (read the conditions below): Unscrew bolts (arrows) and detach bottom section of intake manifold (left-side), paying attention to MPI fuel line. [Note: Renew seals after removing.]

Don't miss

  • Place a cloth underneath to catch escaping fuel.
  • Renew seals after removing.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Remove supercharger (see the separate procedure).
  1. Move fuel hose (1) clear at MPI fuel rail.
  2. Unplug electrical connectors (4) and move electrical wiring clear. [Note: Place a cloth underneath to catch escaping fuel.]
  1. Release hose clip (2) and detach fuel hose.
  2. Remove bolts (3) and (arrow).
  3. Disconnect vacuum hose (2).
  4. Unscrew bolts (arrows) and detach bottom section of intake manifold (right-side), paying attention to MPI fuel line (3).
  5. Unplug electrical connector (1).
  1. Move vacuum hoses clear at fuel rail for MPI injection system. [Note: Place a cloth underneath to catch escaping fuel.]
  1. Release hose clip (2) and detach fuel hose.
  2. Unplug electrical connectors (3) and move electrical wiring clear.
  3. Remove bolts (1) and (arrows).
  4. Unplug electrical connector (2) and disconnect vacuum hose (1).
  5. Unscrew bolts (arrows) and detach bottom section of intake manifold (left-side), paying attention to MPI fuel line. [Note: Renew seals after removing.]
  1. ⚠ Risk of damage to intake manifold flaps. To prevent the intake manifold flaps from catching on the guide plates in the cylinder head, the flaps must be in the power mode position (arrows) (intake passage fully open) when the intake manifold (bottom section) is installed. — Connect hand vacuum pump VAS 6213 to vacuum unit (right-side), as shown in illustration.
  2. Use vacuum pump to generate a vacuum.
  1. Connect hand vacuum pump VAS 6213 to vacuum hose (1) for vacuum unit (left-side), as shown in illustration.
  2. Use vacuum pump to generate a vacuum.
  1. Tighten bolts and nuts for intake manifold (bottom section).
  2. Press intake manifold (bottom section) with fuel rail evenly onto injectors.
  3. Disconnect hand vacuum pump from vacuum unit/vacuum hose.
  4. Install supercharger (see the separate procedure).

📐 6 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 6 workshop diagrams for this job Ask about your Audi CREC — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.