Checking fuel delivery of metering pump V54 with auxiliary heater switched on: Audi
Checking fuel delivery of metering pump V54 with auxiliary heater switched on — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Checking fuel delivery of metering pump
V54 with auxiliary heater switched on
Note
As coolant is only circulated in the small coolant circuit in auxiliary heating mode with the engine stopped on vehicles with heater coolant shut-off valve
N279
, the engine has to be started for implementation of this test. When the engine is running, the heater coolant shut-off valve
N279 is not actuated, the coolant circulates in the large circuit and does not heat up as quickly.
This test measures the metering pump delivery rate in auxiliary heater full load mode. Consequently, the result is not as accurate as when checking delivery by way of the basic setting function. This test does however make it possible to detect any constrictions (e.g. a clogged filter in the burner element) impeding the entry of fuel into the combustion chamber.
A timer which indicates seconds is required for this test.
WARNING
Observe the applicable rules for cleanliness, take the appropriate precautions and heed the relevant safety measures when working on open fuel systems
Engine, mechanics; Rep. Gr. 20; Fuel supply system or
Fuel supply system; Rep. Gr. 20.
Special tools and workshop equipment required
Vehicle diagnostic, testing and information system
VAS 5051 A
Bottle for additional heater
VAS 5086
Clock with second display
Test procedure
Test conditions satisfied
Remove cover (1) at bottom rear right, at vehicle floor.
Disconnect fuel pipe (B) from metering pump (C).
Seal fuel pipe with plug (A).
Pour precisely measured quantity of fuel (e.g. 0.5 l) into bottle for additional heater
VAS 5086.
Note
A rising tube must be fitted to bottle for additional heater
VAS 5086 which reaches to bottom of bottle.
There must be an opening in the container lid to prevent a vacuum from forming when fuel is removed.
Fasten bottle for additional heater
VAS 5086 to vehicle in area of metering pump
V54.
Press bottle for additional heater
VAS 5086 together until fuel is present at end of hose (D)
, then connect hose to metering pump (C).
With the ignition switched off, connect up the vehicle diagnostic, testing and information system
VAS 5051 A with the diagnostic cable
VAS 5051/5A to the 16-pin diagnosis socket in the vehicle
"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Switch ignition on and all electr. loads off.
For
“Convenience” version air conditioner, select temperature setting
“HI” for driver's and front passenger's side on operating and display unit (
Climatronic control unit
J255 or, for
“Basic” version air conditioner, set both temperature rotary controls to
“Maximum heating output”.
For
“Convenience” version air conditioner, limit fresh-air blower speed to blower setting
“5” on operating and display unit (
Climatronic control unit
J255 or, for
“Basic” version air conditioner, set rotary control for fresh-air blower speed to
“Half speed”.
Start guided fault-finding for the supplementary heater control unit
J364
"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Select the function
“Reading measured value block”.
Select the display group in which the operating status of the auxiliary heater is indicated
"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Open all vehicle windows.
Switch on the auxiliary heater (e.g. for an air conditioner of
“Convenience” type on the operating and display unit,
Climatronic control unit
J255) (see the separate procedure).
Observe the display in which actuation of the metering pump
V54 is indicated.
Start measuring the time as soon as the display indicates that the metering pump
V54 is being actuated at more than 80%.
Continue to observe the display. If the metering pump
V54 is actuated at less than 80% within the measurement period, eliminate the cause of the trouble and repeat the test.
Switch off auxiliary heater after 5 minutes in full- load mode (metering pump actuation greater than 80%).
Terminate guided fault-finding.
Switch off ignition and detach diagnostic connector.
Remove
bottle for additional heater
VAS 5086 and measure remaining fuel.
In the 5 minute full-load period (actuation of metering pump
V54 at more than 80 %), metering pump
V54 must deliver at least 47 ml on vehicles with petrol engine and at least 40 ml on vehicles with diesel engine.
Note
One millilitre (ml) corresponds to (1)
/
1000 litre or cm (3).
A metering pump
V54 with an actual delivery capacity of 100% (permissible tolerance ± 10 %) which is actuated at 100% over the entire 5 minute period by the auxiliary heater control unit
J364
, will deliver 58.5 ml (300 seconds x 6.3 pulses per second x 0.031 ml per stroke) on vehicles with petrol engine and 50 ml (300 seconds x 5.37 pulses per second x 0.031 ml per stroke) on vehicles with diesel engine.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking fuel delivery (of metering pump -V54)
- Checking fuel delivery of metering pump -V54 (heater type "Z/C")
- Checking fuel delivery rate of metering pump -V54
- Checking fuel delivery volume of metering pump with auxiliary heater switched on
- Bleeding fuel line to metering pump V54 (filling with fuel)
- Bleeding fuel supply line leading to metering pump, vehicles with auxiliary heater
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.