Bleeding fuel line to metering pump
V54 (filling with fuel)
Note
Air/fuel vapour in the fuel supply to the auxiliary heater can lead to problems in auxiliary heater operation. To stop air/fuel vapour being drawn in by the metering pump
V54 and conveyed to the auxiliary heater when the auxiliary heater is first switched on after working on the fuel tank or fuel delivery unit, the fuel take-off pipe must be filled with fuel (bled) after working in this area.
The fuel line must be bled, for example if the fuel line was removed and the entire fuel line is filled with air. For example, if only the fuel delivery unit was removed and there is only a small amount of air in the fuel line, it is sufficient to switch on the auxiliary heater and let it run for some time at full load (at least 10 minutes) to check its operation after completing work on the fuel system.
After working on the fuel system, switch on the auxiliary heater and let it run for at least 10 minutes at full load to check operation.
On vehicles with high-voltage system, it may not be possible to switch on the auxiliary heater via the Multi Media Interface (MMI); this depends on the charge level of the hybrid battery unit
AX1 and the ambient temperature. If
J255 is informed that the hybrid battery unit
AX1 is charged sufficiently and that enough energy is available to operate the high-voltage heater (PTC)
Z115 and if the ambient temperature is above -10°C, it activates
Z115 (the auxiliary heater is not activated). In this case, the auxiliary heater can be activated via the
“Basic setting” function, for example. For further information, refer to (see the separate procedure) and
Vehicle diagnostic tester in
“Guided Fault Finding” mode.
Vehicles without high-voltage system
Auxiliary heater is switched off ( metering pump
V54 is not activated).
Switch off electrical equipment.
Switch off ignition.
Remove
metering pump
V54 (see the separate procedure).
Unfasten O-type clip and detach fuel hose (2) from pump (1).
Connect fuel hose (2) to hose (3) of diesel extractor
VAS 5226.
Connect diesel extractor
VAS 5226 to workshop's compressed-air system.
Completely fill fuel line with fuel by briefly extracting air.
Connect fuel line (2) to metering pump
V54 (1) with new O-type clip.
After re-installing all the components removed previously, switch on the auxiliary heater and let it run at full load for approx. 10 minutes.
Vehicles with high-voltage system
Note
The metering pump
V54 (1) cannot be accessed on vehicles with high-voltage system if the fuel tank is installed. The fuel line (2) (and the corresponding riser) to the metering pump
V54 must therefore be bled after working on the fuel system (e.g. after working on the fuel delivery unit or
V54 (1)).
Disconnect fuel line (4) (from
V54 (1) to auxiliary heater) at connection (5) (repair group 20: Plug-in connectors; Disconnecting plug-in connectors).
Note
Observe safety precautions when working on the fuel supply system (repair group 00: Safety precautions; Safety precautions when working on the fuel supply system).
Hold a container under the open connection (e.g. container for diesel extractor
VAS 5226).
Activate
V54 (1) for 30 seconds, e.g. via the
“Pipe filling” function under
“Basic setting”
Vehicle diagnostic tester in
“Guided Fault Finding” mode.
Observe fuel coming out at connection (5).
Note
If there is a continuous flow of fuel coming out at the connection (5) after 30 seconds, the fuel line is completely filled with fuel.
Assemble fuel line at connection (5).
After re-installing all the components removed previously, switch on the auxiliary heater and let it run at full load for approx. 10 minutes.
Note
On vehicles with high-voltage system, it may not be possible to switch on the auxiliary heater via the Multi Media Interface (MMI); this depends on the charge level of the hybrid battery unit
AX1 and the ambient temperature. If
J255 is informed that the hybrid battery unit
AX1 is charged sufficiently and that enough energy is available to operate the high-voltage heater (PTC)
Z115 and if the ambient temperature is above -10°C, it activates
Z115 (the auxiliary heater is not activated). In this case, the auxiliary heater can be activated via the
“Basic setting” function, for example. For further information, refer to (see the separate procedure) and
Vehicle diagnostic tester in
“Guided Fault Finding” mode.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Bleeding fuel supply line leading to metering pump, vehicles with auxiliary heater
- Bleeding fuel line to metering pump V54 (filling with fuel)
- Checking fuel delivery (of metering pump -V54)
- Checking fuel delivery of metering pump -V54 (heater type "Z/C")
- Checking fuel delivery of metering pump V54 with auxiliary heater switched on
- Checking fuel delivery rate of metering pump -V54
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.